Dose-efficient phase-contrast imaging of thick weak phase objects via OBF STEM using a pixelated detector

Optimum bright-field scanning transmission electron microscopy (OBF STEM) is a recently developed low-dose imaging technique that uses a segmented or pixelated detector. While we previously reported that OBF STEM with a segmented detector has a higher efficiency than conventional STEM techniques such as annular bright field (ABF), the imaging efficiency is expected to be further improved by using a pixelated detector. In this study, we adopted a pixelated detector for the OBF technique and investigated the imaging characteristics. Because OBF imaging is based on the thick weak phase object approximation (tWPOA), a non-zero crystalline sample thickness is considered in addition to the conventional WPOA, where the pixelated OBF method can be regarded as the theoretical extension of single side band (SSB) ptychography. Thus, we compared these two techniques via signal-to-noise ratio transfer functions (SNRTFs), multi-slice image simulations, and experiments, showing how the OBF technique can improve dose efficiency from the conventional WPOA-based ptychographic imaging.

Authors

Institutions

Publication Details

Journal
Microscopy
Published
2024-11-07
DOI
https://doi.org/10.1093/jmicro/dfae051
Citations
5
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
3.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dose-efficient phase-contrast imaging of thick weak phase objects via OBF STEM using a pixelated detector

Yuichi Ikuhara, Kousuke Ooe, Takehito Seki, Naoya Shibata et al.
5 citations
Microscopy
Advanced X-ray Imaging Techniques
3.04
article

Dose-efficient phase-contrast imaging of thick weak phase objects via OBF STEM using a pixelated detector

Yuichi Ikuhara, Kousuke Ooe, Takehito Seki, Naoya Shibata, Mitsuru Nogami
article en
5 citations

Abstract

Optimum bright-field scanning transmission electron microscopy (OBF STEM) is a recently developed low-dose imaging technique that uses a segmented or pixelated detector. While we previously reported that OBF STEM with a segmented detector has a higher efficiency than conventional STEM techniques such as annular bright field (ABF), the imaging efficiency is expected to be further improved by using a pixelated detector. In this study, we adopted a pixelated detector for the OBF technique and investigated the imaging characteristics. Because OBF imaging is based on the thick weak phase object approximation (tWPOA), a non-zero crystalline sample thickness is considered in addition to the conventional WPOA, where the pixelated OBF method can be regarded as the theoretical extension of single side band (SSB) ptychography. Thus, we compared these two techniques via signal-to-noise ratio transfer functions (SNRTFs), multi-slice image simulations, and experiments, showing how the OBF technique can improve dose efficiency from the conventional WPOA-based ptychographic imaging.

MicroscopyVol. 74(2)
Japan Science and Technology Agency (JP), Institute of Engineering (NP), Japan Fine Ceramics Center (JP), The University of Tokyo (JP)
Affordable and clean energy
Openalex Percentile: Top 9%
Advanced X-ray Imaging Techniques
3.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Dose-efficient phase-contrast imaging of thick weak phase objects via OBF STEM using a pixelated detector — Yuichi Ikuhara, Kousuke Ooe, et al. · Microscopy (2024) | TGRS Research Map | TGRS