Evaluation of a Novel Femtosecond Laser Ablation System for In Situ Analysis Based on Two-Dimensional Galvanometer Scanners

Uneven energy distribution of femtosecond lasers presents a significant challenge for single-spot analysis, which often leads to concave ablation craters. This study assesses the performance of a femtosecond laser ablation system for in situ analysis using novel galvanometer scanners. A galvanometer rapidly moved the laser beam focus to create craters with a small beam spot. We first examined the inductively coupled plasma mass spectrometry (ICP-MS) signal sensitivity to laser parameters, establishing a strong linear correlation with the laser energy, repetition rate, scanning ablation area, and galvanometer scanning frequency. Elemental fractionation analysis of NIST SRM 610 suggests minimal bias, with fractionation indices of different elements approaching unity. Subsequently, the elemental concentration of six reference material glasses was measured by fsLA-ICP-MS to evaluate the elemental quantification capabilities of the Galvo-femtosecond laser (Galvo-fsLA). The laser's capability for in situ U-Pb dating was demonstrated by concordant U-Pb ages of five zircon reference materials that are highly consistent with the ID-TIMS ages reported previously. Finally, the reliability of the new Galvo-fsLA for isotope analysis was verified by the accurate determination of radiogenic Hf, Pb isotopes, and stable Cu isotopes, all agreeing well with their reference values within uncertainties. These assessments underscore the significant potential of Galvo-fsLA for enhanced accuracy and precision of single-spot in situ analysis.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2024-11-06
DOI
https://doi.org/10.1021/acs.analchem.4c01291
Citations
4
Primary Topic
Laser-induced spectroscopy and plasma
Type
article
Field-Weighted Citation Impact
1.08

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of a Novel Femtosecond Laser Ablation System for In Situ Analysis Based on Two-Dimensional Galvanometer Scanners

Yi Hu, Xiaojuan Nie, Jing Tian, Honglin Yuan et al.
4 citations
Analytical Chemistry
Laser-induced spectroscopy and plasma
1.08
article

Evaluation of a Novel Femtosecond Laser Ablation System for In Situ Analysis Based on Two-Dimensional Galvanometer Scanners

Yi Hu, Xiaojuan Nie, Jing Tian, Honglin Yuan, Zhongqiang Wang, Nan Lv, Kaiyun Chen, Zhian Bao, Deyi Peng, Yan Liang
article en
4 citations

Abstract

Uneven energy distribution of femtosecond lasers presents a significant challenge for single-spot analysis, which often leads to concave ablation craters. This study assesses the performance of a femtosecond laser ablation system for in situ analysis using novel galvanometer scanners. A galvanometer rapidly moved the laser beam focus to create craters with a small beam spot. We first examined the inductively coupled plasma mass spectrometry (ICP-MS) signal sensitivity to laser parameters, establishing a strong linear correlation with the laser energy, repetition rate, scanning ablation area, and galvanometer scanning frequency. Elemental fractionation analysis of NIST SRM 610 suggests minimal bias, with fractionation indices of different elements approaching unity. Subsequently, the elemental concentration of six reference material glasses was measured by fsLA-ICP-MS to evaluate the elemental quantification capabilities of the Galvo-femtosecond laser (Galvo-fsLA). The laser's capability for in situ U-Pb dating was demonstrated by concordant U-Pb ages of five zircon reference materials that are highly consistent with the ID-TIMS ages reported previously. Finally, the reliability of the new Galvo-fsLA for isotope analysis was verified by the accurate determination of radiogenic Hf, Pb isotopes, and stable Cu isotopes, all agreeing well with their reference values within uncertainties. These assessments underscore the significant potential of Galvo-fsLA for enhanced accuracy and precision of single-spot in situ analysis.

Analytical ChemistryVol. 96(46)
Northwest University (CN), Shanghai Optical Instrument Research Institute (CN), State Key Laboratory of Continental Dynamics
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 26%
Laser-induced spectroscopy and plasma
1.08
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.