Abstract Metamaterials or metamaterial‐inspired structures/resonators have yielded significant advancement in the imaging capabilities of Magnetic Resonance Imaging (MRI) by boosting its performance parameter, i.e., signal‐to‐noise ratio (SNR). Metamaterials have a distinctive ability to boost and redistribute magnetic fields inside the subject undergoing scan when integrated as accessories between receive arrays and the subject. However, the translation of most reported metamaterials into a clinical accessory is still limited and challenging due to their low sensitivity, sub‐optimal performance, and bulky footprints for integration inside MRI scanners. Herein, a metamaterial‐inspired structure is developed using coupled octa‐spiral resonators to boost magnetic field localization inside the scanned region. In addition, the high‐Q resonance of the metamaterial‐inspired structure improves impedance matching and enhances the transmit/receive efficiency of MRI coils. Theoretical analysis of electromagnetic responses and full‐wave simulations show a homogeneous boost in SNR by over times throughout a human‐properties mimicking phantom using the resonator with a maximum SNR enhancement factor (EF) of . The spatial distribution of SNR EF inside the phantom is also validated by preliminary laboratory experiments. Thus, the developed coupled octa‐spirals resonator can pave the way for developing and adopting metamaterial‐inspired devices as clinical accessories for facilitating better, faster, and cost‐effective MRI scans.

Authors

Institutions

Publication Details

Journal
Advanced Theory and Simulations
Published
2024-11-07
DOI
https://doi.org/10.1002/adts.202400848
Citations
4
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.62
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving Signal‐to‐Noise Ratio of 1.5T MRI Scans Using High‐Q Resonators Based on Coupled Octa‐Spirals

Debabrata Sikdar, S. Kanagaraj, Jegyasu Gupta, Ratnajit Bhattacharjee
4 citations
Advanced Theory and Simulations
Advanced MRI Techniques and Applications
1.62
article

Improving Signal‐to‐Noise Ratio of 1.5T MRI Scans Using High‐Q Resonators Based on Coupled Octa‐Spirals

Debabrata Sikdar, S. Kanagaraj, Jegyasu Gupta, Ratnajit Bhattacharjee
article en
4 citations

Abstract

Abstract Metamaterials or metamaterial‐inspired structures/resonators have yielded significant advancement in the imaging capabilities of Magnetic Resonance Imaging (MRI) by boosting its performance parameter, i.e., signal‐to‐noise ratio (SNR). Metamaterials have a distinctive ability to boost and redistribute magnetic fields inside the subject undergoing scan when integrated as accessories between receive arrays and the subject. However, the translation of most reported metamaterials into a clinical accessory is still limited and challenging due to their low sensitivity, sub‐optimal performance, and bulky footprints for integration inside MRI scanners. Herein, a metamaterial‐inspired structure is developed using coupled octa‐spiral resonators to boost magnetic field localization inside the scanned region. In addition, the high‐Q resonance of the metamaterial‐inspired structure improves impedance matching and enhances the transmit/receive efficiency of MRI coils. Theoretical analysis of electromagnetic responses and full‐wave simulations show a homogeneous boost in SNR by over times throughout a human‐properties mimicking phantom using the resonator with a maximum SNR enhancement factor (EF) of . The spatial distribution of SNR EF inside the phantom is also validated by preliminary laboratory experiments. Thus, the developed coupled octa‐spirals resonator can pave the way for developing and adopting metamaterial‐inspired devices as clinical accessories for facilitating better, faster, and cost‐effective MRI scans.

Advanced Theory and SimulationsVol. 8(2)
Indian Institute of Technology Guwahati (IN), Indian Institute of Information Technology Guwahati (IN)
Openalex Percentile: Top 15%
Advanced MRI Techniques and Applications
1.62
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Improving Signal‐to‐Noise Ratio of 1.5T MRI Scans Using High‐Q Resonators Based on Coupled Octa‐Spirals — Debabrata Sikdar, S. Kanagaraj, et al. · Advanced Theory and Simulations (2024) | TGRS Research Map | TGRS