Clinical Comparison of OC-Sensor Pledia and Phadia 250 for Fecal Calprotectin Testing

<b>Background:</b> The fecal calprotectin (f-Cal) test is a convenient method used for differentiating inflammatory bowel disease (IBD) from functional bowel disorders. The OC-Sensor Pledia (OC-FCa; Eiken Chemical Co., Tokyo, Japan) is a latex agglutination turbidimetric immunoassay used for f-Cal measurements. We evaluated the clinical performance of OC-FCa and compared the f-Cal levels between OC-FCa and Phadia 250 (Thermo Fisher Scientific, Freiburg, Germany). <b>Methods:</b> We collected 278 stool samples; of these, 158 were taken from patients with suspected IBD, and 120 were taken from healthy individuals. We analyzed the f-Cal distribution in each group and compared the clinical performance and agreement between OC-FCa and Phadia 250. <b>Results:</b> The f-Cal of patients with IBD was significantly different from that of patients without IBD for both OC-FCa and Phadia 250 (<i>p</i> < 0.0001 and <i>p</i> < 0.001, respectively). The concordance between OC-FCa and Phadia 250 was 82.3%, with moderate agreement (kappa = 0.644, 95% confidence interval = 0.525-0.763). OC-FCa and Phadia 250 showed a high correlation (r = 0.90); their diagnostic performance showed moderate accuracy (AUC = 0.873 and 0.866, respectively) and had no significant difference (<i>p</i> = 0.616). <b>Conclusions:</b> Both OC-FCa and Phadia 250 showed a high correlation and good clinical performance. F-Cal measured using OC-FCa was reliable for initial differentiation between patients with IBD and without IBD. Therefore, OC-FCa and Phadia 250 could be alternative devices for measuring f-Cal depending on the laboratory situation.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2024-11-07
DOI
https://doi.org/10.3390/diagnostics14222490
Primary Topic
Nutrition and Health in Aging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical Comparison of OC-Sensor Pledia and Phadia 250 for Fecal Calprotectin Testing

Yeo‐Min Yun, Jong Do Seo, Hee‐Won Moon, Hanah Kim et al.
Diagnostics
Nutrition and Health in Aging
article

Clinical Comparison of OC-Sensor Pledia and Phadia 250 for Fecal Calprotectin Testing

Yeo‐Min Yun, Jong Do Seo, Hee‐Won Moon, Hanah Kim, Hee Sook Shim, Eunju Shin, Mina Hur
article en

Abstract

<b>Background:</b> The fecal calprotectin (f-Cal) test is a convenient method used for differentiating inflammatory bowel disease (IBD) from functional bowel disorders. The OC-Sensor Pledia (OC-FCa; Eiken Chemical Co., Tokyo, Japan) is a latex agglutination turbidimetric immunoassay used for f-Cal measurements. We evaluated the clinical performance of OC-FCa and compared the f-Cal levels between OC-FCa and Phadia 250 (Thermo Fisher Scientific, Freiburg, Germany). <b>Methods:</b> We collected 278 stool samples; of these, 158 were taken from patients with suspected IBD, and 120 were taken from healthy individuals. We analyzed the f-Cal distribution in each group and compared the clinical performance and agreement between OC-FCa and Phadia 250. <b>Results:</b> The f-Cal of patients with IBD was significantly different from that of patients without IBD for both OC-FCa and Phadia 250 (<i>p</i> < 0.0001 and <i>p</i> < 0.001, respectively). The concordance between OC-FCa and Phadia 250 was 82.3%, with moderate agreement (kappa = 0.644, 95% confidence interval = 0.525-0.763). OC-FCa and Phadia 250 showed a high correlation (r = 0.90); their diagnostic performance showed moderate accuracy (AUC = 0.873 and 0.866, respectively) and had no significant difference (<i>p</i> = 0.616). <b>Conclusions:</b> Both OC-FCa and Phadia 250 showed a high correlation and good clinical performance. F-Cal measured using OC-FCa was reliable for initial differentiation between patients with IBD and without IBD. Therefore, OC-FCa and Phadia 250 could be alternative devices for measuring f-Cal depending on the laboratory situation.

DiagnosticsVol. 14(22)
Konkuk University (KR)
Konkuk University Medical Center, Konkuk University
Openalex Percentile: Top 72%
Nutrition and Health in Aging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.