Improvement of plan quality in whole-breast radiation following BCS using feasibility DVH by less-experienced planners

Variability in plan quality of radiotherapy is commonly attributed to the planner's skill rather than technological parameters. While experienced planners can set reasonable parameters before optimization, less experienced planners face challenges. This study aimed to assess the quality of volumetric-modulated arc therapy (VMAT) in patients with left-sided breast cancer following breast-conserving surgery. Twenty-eight patients requiring whole-breast irradiation were randomly selected for inclusion. Each patient underwent two VMAT treatment plans: one optimized by an experienced planner (VMAT-EXP group) and the other designed by a less experienced planner using feasibility dose-volume histogram (FDVH) parameters from PlanIQ (VMAT-FDVH group). Both plans aimed to deliver a prescription dose of 50 Gy in 25 fractions to the planning target volume (PTV). Dosimetry parameters for the PTV and organs at risk (OARs) were compared between the two groups. Both the VMAT-EXP and VMAT-FDVH groups met the clinical plan goals for PTV and OARs. VMAT-FDVH demonstrated a PTV coverage and homogeneity comparable to those of VMAT-EXP. Compared to VMAT-EXP plans, VMAT-FDVH plans resulted in a significant reduction in the mean ipsilateral lung dose, with an average decrease of 0.9 Gy (8.5 Gy vs. 7.6 Gy, P < 0.001). The V5Gy and V20Gy of the ipsilateral lung were also reduced by 3.2% and 1.8%, respectively. Minor differences were observed in the heart, contralateral lung, breast, and liver. Personalized objectives derived from the feasibility DVH tool facilitated the generation of acceptable VMAT plans. Less experienced planners achieved lower doses to the ipsilateral lung while maintaining adequate target coverage and homogeneity. These findings suggest the potential for the effective use of VMAT in in patients with left-sided breast cancer following breast-conserving surgery, especially when guided by feasibility DVH parameters.

Authors

Institutions

Publication Details

Journal
Physical and Engineering Sciences in Medicine
Published
2024-11-07
DOI
https://doi.org/10.1007/s13246-024-01493-y
Primary Topic
Breast Cancer Treatment Studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improvement of plan quality in whole-breast radiation following BCS using feasibility DVH by less-experienced planners

Mingming Luo, Changfei Gong, Xiaoping Wang, Yun Zhang et al.
Physical and Engineering Sciences in Medicine
Breast Cancer Treatment Studies
article

Improvement of plan quality in whole-breast radiation following BCS using feasibility DVH by less-experienced planners

Mingming Luo, Changfei Gong, Xiaoping Wang, Yun Zhang, Yuling Huang, Xingxing Yuan
article en

Abstract

Variability in plan quality of radiotherapy is commonly attributed to the planner's skill rather than technological parameters. While experienced planners can set reasonable parameters before optimization, less experienced planners face challenges. This study aimed to assess the quality of volumetric-modulated arc therapy (VMAT) in patients with left-sided breast cancer following breast-conserving surgery. Twenty-eight patients requiring whole-breast irradiation were randomly selected for inclusion. Each patient underwent two VMAT treatment plans: one optimized by an experienced planner (VMAT-EXP group) and the other designed by a less experienced planner using feasibility dose-volume histogram (FDVH) parameters from PlanIQ (VMAT-FDVH group). Both plans aimed to deliver a prescription dose of 50 Gy in 25 fractions to the planning target volume (PTV). Dosimetry parameters for the PTV and organs at risk (OARs) were compared between the two groups. Both the VMAT-EXP and VMAT-FDVH groups met the clinical plan goals for PTV and OARs. VMAT-FDVH demonstrated a PTV coverage and homogeneity comparable to those of VMAT-EXP. Compared to VMAT-EXP plans, VMAT-FDVH plans resulted in a significant reduction in the mean ipsilateral lung dose, with an average decrease of 0.9 Gy (8.5 Gy vs. 7.6 Gy, P < 0.001). The V5Gy and V20Gy of the ipsilateral lung were also reduced by 3.2% and 1.8%, respectively. Minor differences were observed in the heart, contralateral lung, breast, and liver. Personalized objectives derived from the feasibility DVH tool facilitated the generation of acceptable VMAT plans. Less experienced planners achieved lower doses to the ipsilateral lung while maintaining adequate target coverage and homogeneity. These findings suggest the potential for the effective use of VMAT in in patients with left-sided breast cancer following breast-conserving surgery, especially when guided by feasibility DVH parameters.

Physical and Engineering Sciences in MedicineVol. 48(1)
Jiangxi Provincial Cancer Hospital (CN)
National Natural Science Foundation of China, Natural Science Foundation of Jiangxi Province
Good health and well-being
Openalex Percentile: Top 71%
Breast Cancer Treatment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.