High-count-rate particle tracking in proton and carbon radiotherapy with Timepix2 operated in ultra-short acquisition time

Abstract This work investigates the operational acquisition time limits of Timepix3 and Timepix2 detectors operated in frame mode for high-count rate of high deposited energy transfer particles. Measurements were performed using alpha particles from a 241 Am laboratory source and proton and carbon ion beams from a synchrotron accelerator. The particle count rate upper limit is determined by overlapping per-pixel particle signals, identifiable by the hits per pixel counter > 2, indicating the need to decrease acquisition time. On the other hand, the lower limit is the time required to collect the particle deposited charge while maintaining spectral properties. Different acquisition times were evaluated for an AdvaPIX Timepix3 detector (500 μm Silicon sensor) with standard per-pixel Digital to Analog Converter (DAC) settings and a Minipix Timepix2 detector (300 μm Silicon sensor) with standard and customized settings the pulse shaping parameter and threshold. For AdvaPIX Timepix3, spectra remained accurate down to 100 μs frame acquisition time; at 10 μs, loss of collected charge occurred, suggesting either avoiding this acquisition time or applying a correction. Timepix2 allowed acquisition times down to 100 ns for single particle track measurements even for high energy loss, enabled by a new Timepix2 feature delaying shutter closure until full particle charge collection. This work represents the first measurement utilizing Timepix-chips pixel detectors in an accelerator beam of clinical energy and intensity without the need to decrease the beam current. This is made possible by exploiting the short shutter feature in Timepix2 and a customized per-pixel energy calibration of the Timepix2 detector with a larger discharging signal value which allowed for shorter Time-over-Threshold (ToT) signal. These customized settings extend the operation of the pixel detectors to higher event rates up to 10 9 particles/cm 2 /s.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2024-11-01
DOI
https://doi.org/10.1088/1748-0221/19/11/c11002
Citations
6
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
3.96
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-count-rate particle tracking in proton and carbon radiotherapy with Timepix2 operated in ultra-short acquisition time

Lukáš Marek, Sandra Barna, Cristina Oancea, Carlos Granja et al.
6 citations
Journal of Instrumentation
Particle Detector Development and Performance
3.96
article

High-count-rate particle tracking in proton and carbon radiotherapy with Timepix2 operated in ultra-short acquisition time

Lukáš Marek, Sandra Barna, Cristina Oancea, Carlos Granja, Loïc Grevillot, Giulio Magrin, D. Hladik, Andreas Resch, J. Jakůbek
article en
6 citations

Abstract

Abstract This work investigates the operational acquisition time limits of Timepix3 and Timepix2 detectors operated in frame mode for high-count rate of high deposited energy transfer particles. Measurements were performed using alpha particles from a 241 Am laboratory source and proton and carbon ion beams from a synchrotron accelerator. The particle count rate upper limit is determined by overlapping per-pixel particle signals, identifiable by the hits per pixel counter > 2, indicating the need to decrease acquisition time. On the other hand, the lower limit is the time required to collect the particle deposited charge while maintaining spectral properties. Different acquisition times were evaluated for an AdvaPIX Timepix3 detector (500 μm Silicon sensor) with standard per-pixel Digital to Analog Converter (DAC) settings and a Minipix Timepix2 detector (300 μm Silicon sensor) with standard and customized settings the pulse shaping parameter and threshold. For AdvaPIX Timepix3, spectra remained accurate down to 100 μs frame acquisition time; at 10 μs, loss of collected charge occurred, suggesting either avoiding this acquisition time or applying a correction. Timepix2 allowed acquisition times down to 100 ns for single particle track measurements even for high energy loss, enabled by a new Timepix2 feature delaying shutter closure until full particle charge collection. This work represents the first measurement utilizing Timepix-chips pixel detectors in an accelerator beam of clinical energy and intensity without the need to decrease the beam current. This is made possible by exploiting the short shutter feature in Timepix2 and a customized per-pixel energy calibration of the Timepix2 detector with a larger discharging signal value which allowed for shorter Time-over-Threshold (ToT) signal. These customized settings extend the operation of the pixel detectors to higher event rates up to 10 9 particles/cm 2 /s.

Journal of InstrumentationVol. 19(11)
Advacam (Czechia) (CZ), MedAustron (AT), Medical University of Vienna (AT)
Affordable and clean energy
Openalex Percentile: Top 5%
Particle Detector Development and Performance
3.96
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.