Indirect determination of free chlorine in seawater by cyclic voltammetry using graphite–epoxy composite electrode: Hydrogen adsorption capacity of graphite–epoxy composite is one–third of that of platinum

A new possibility of indirect determination of free chlorine using a graphite–epoxy composite(GEC) electrode instead of Pt disk electrode was suggested by interpreting the relationship between the peak current of the oxidation peak for hydrogen generated through water electrolysis in CV and the amount of the free chlorine. The linear response range of concentration was 0.06–0.2 mg∙L −1 with correlation coefficient of 0.9951 ( n = 5) and the sensitivity of 1225 μA cm −2 mg −1 L. The limit of detection (LOD) calculated from the 3 σ IUPAC criteria was 1.2 × 10 −2 mg L −1 . The relative standard deviation ( RSD ) to 0.06 mg L −1 was 4.65 %( n = 10). The results show that the amount of free chlorine in the disinfected seawater can be indirectly determined by using a GEC electrode without influence of interferences unlike a Pt disk electrode. On the other hand, in this paper, a new method is proposed to evaluate the relative hydrogen adsorption capacity by the sensitivity of GEC electrode compared with that of Pt disk electrode. During the investigation of the hydrogen adsorption on the surface of the working electrode, we obtained the result that the hydrogen adsorption capacity of GEC is one-third of that of platinum. • Firstly, it was described the determination method of free chlorine by graphite–epoxy composite (GEC) instead of by Pt. • Secondly, it was proposed the new evaluation method of the relative hydrogen adsorption capability.

Authors

Institutions

Publication Details

Journal
Sensing and Bio-Sensing Research
Published
2024-11-07
DOI
https://doi.org/10.1016/j.sbsr.2024.100711
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Indirect determination of free chlorine in seawater by cyclic voltammetry using graphite–epoxy composite electrode: Hydrogen adsorption capacity of graphite–epoxy composite is one–third of that of platinum

Kye Hak Ko
Sensing and Bio-Sensing Research
Electrochemical Analysis and Applications
article

Indirect determination of free chlorine in seawater by cyclic voltammetry using graphite–epoxy composite electrode: Hydrogen adsorption capacity of graphite–epoxy composite is one–third of that of platinum

Kye Hak Ko
article en

Abstract

A new possibility of indirect determination of free chlorine using a graphite–epoxy composite(GEC) electrode instead of Pt disk electrode was suggested by interpreting the relationship between the peak current of the oxidation peak for hydrogen generated through water electrolysis in CV and the amount of the free chlorine. The linear response range of concentration was 0.06–0.2 mg∙L −1 with correlation coefficient of 0.9951 ( n = 5) and the sensitivity of 1225 μA cm −2 mg −1 L. The limit of detection (LOD) calculated from the 3 σ IUPAC criteria was 1.2 × 10 −2 mg L −1 . The relative standard deviation ( RSD ) to 0.06 mg L −1 was 4.65 %( n = 10). The results show that the amount of free chlorine in the disinfected seawater can be indirectly determined by using a GEC electrode without influence of interferences unlike a Pt disk electrode. On the other hand, in this paper, a new method is proposed to evaluate the relative hydrogen adsorption capacity by the sensitivity of GEC electrode compared with that of Pt disk electrode. During the investigation of the hydrogen adsorption on the surface of the working electrode, we obtained the result that the hydrogen adsorption capacity of GEC is one-third of that of platinum. • Firstly, it was described the determination method of free chlorine by graphite–epoxy composite (GEC) instead of by Pt. • Secondly, it was proposed the new evaluation method of the relative hydrogen adsorption capability.

Sensing and Bio-Sensing ResearchVol. 46
Kim Chaek University of Technology (KP)
Life below water
Openalex Percentile: Top 83%
Electrochemical Analysis and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.