Continuous-flow analysis of nitrogen compounds in environmental water using a copper–zinc reduction coil

• Copper–zinc reduction CFA method is cadmium-free and can determine nitrogen compounds • Influence of metal precipitation can be removed by changing reagent conditions • Copper–zinc reduction CFA method shows high accuracy in environmental water analysis The copper–cadmium reduction method has been applied to determine nitrogen compounds in heavily contaminated environmental water. However, there is an international demand to reduce the use of cadmium because it is harmful to humans and environment. Hence, a copper–zinc reduction continuous flow analysis system without using cadmium was developed for nitrogen‐compound determination. However, the effects of seawater contaminants on this analytical method remains unknown. Therefore, in this study, the effects of contaminants on the developed method are investigated, and the applicability of the method to environmental water analysis is examined. Resultantly, interference due to magnesium precipitation is confirmed; however, this could be prevented by adjusting the concentration of the analytical reagent, i.e,. ethylenediaminetetraacetic acid disodium. The measurement of certified reference materials under the new conditions, with precipitation countermeasures, show good results, with an accuracy of over 96%. Additionally, a recovery study using actual environmental water afforded good results, with recovery of >95% for all samples. These results indicate that the proposed method is an excellent, cadmium-free analytical method capable of analyzing environmental water as effectively as conventional methods.

Authors

Institutions

Publication Details

Journal
Talanta Open
Published
2024-11-07
DOI
https://doi.org/10.1016/j.talo.2024.100378
Citations
2
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.47

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Continuous-flow analysis of nitrogen compounds in environmental water using a copper–zinc reduction coil

Satoshi MORIKUBO, Daisuke Enomoto, Takashi Nishimura, Yasuhiko Takuma et al.
2 citations
Talanta Open
Analytical chemistry methods development
0.47
article

Continuous-flow analysis of nitrogen compounds in environmental water using a copper–zinc reduction coil

Satoshi MORIKUBO, Daisuke Enomoto, Takashi Nishimura, Yasuhiko Takuma, Suguru Okunishi, Yorihiro KUMAZAWA, Ryosei KANNO, Hiroto Maeda, Nodoka TAKAHASHI
article en
2 citations

Abstract

• Copper–zinc reduction CFA method is cadmium-free and can determine nitrogen compounds • Influence of metal precipitation can be removed by changing reagent conditions • Copper–zinc reduction CFA method shows high accuracy in environmental water analysis The copper–cadmium reduction method has been applied to determine nitrogen compounds in heavily contaminated environmental water. However, there is an international demand to reduce the use of cadmium because it is harmful to humans and environment. Hence, a copper–zinc reduction continuous flow analysis system without using cadmium was developed for nitrogen‐compound determination. However, the effects of seawater contaminants on this analytical method remains unknown. Therefore, in this study, the effects of contaminants on the developed method are investigated, and the applicability of the method to environmental water analysis is examined. Resultantly, interference due to magnesium precipitation is confirmed; however, this could be prevented by adjusting the concentration of the analytical reagent, i.e,. ethylenediaminetetraacetic acid disodium. The measurement of certified reference materials under the new conditions, with precipitation countermeasures, show good results, with an accuracy of over 96%. Additionally, a recovery study using actual environmental water afforded good results, with recovery of >95% for all samples. These results indicate that the proposed method is an excellent, cadmium-free analytical method capable of analyzing environmental water as effectively as conventional methods.

Talanta OpenVol. 10
Kagoshima University (JP), Kanto Chemical (Japan) (JP), Tokyo Metropolitan Industrial Technology Research Institute (JP)
Ministry of Economy, Trade and Industry
Clean water and sanitation
Openalex Percentile: Top 40%
Analytical chemistry methods development
0.47
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.