Mitigating Transmission Line Impacts Due to DERs by Ancillary Services Provided by Battery Energy Storage System in a Multi-Area Network

In a multi-area network Distributed Energy Resources(DERs) of one area can significantly impact the transmission line flows of other area. The change in transmission line flows over a longer period will lead to transmission revenue loss for a transmission owner. In this study the feasibility of battery energy storage system providing ancillary service to mitigate the line flow impacts of the non-DER area due to the DERs in a neighboring area is studied. Firstly, the line flow difference of the lines in a non-DER area for the DER and non-DER scenario is captured. The most significant lines of the non-DER area are identified based on the number of hours a line experiences a line flow difference exceeding a predefined threshold. Optimization is conducted to determine the additional battery capacity needed at each DER bus to limit the line flows of the identified significant lines. The results demonstrate that utilizing battery energy storage as ancillary services is an effective strategy for mitigating line flow impacts which in turn reduces the revenue loss for the transmission owner.

Authors

Institutions

Publication Details

Published
2024-10-13
DOI
https://doi.org/10.1109/naps61145.2024.10741611
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mitigating Transmission Line Impacts Due to DERs by Ancillary Services Provided by Battery Energy Storage System in a Multi-Area Network

Visvakumar Aravinthan, Sarangan Rajendran, Al Tamimi, Nirasha Bataduvaarachchi et al.
Microgrid Control and Optimization
article

Mitigating Transmission Line Impacts Due to DERs by Ancillary Services Provided by Battery Energy Storage System in a Multi-Area Network

Visvakumar Aravinthan, Sarangan Rajendran, Al Tamimi, Nirasha Bataduvaarachchi, Demy Alexander
article en

Abstract

In a multi-area network Distributed Energy Resources(DERs) of one area can significantly impact the transmission line flows of other area. The change in transmission line flows over a longer period will lead to transmission revenue loss for a transmission owner. In this study the feasibility of battery energy storage system providing ancillary service to mitigate the line flow impacts of the non-DER area due to the DERs in a neighboring area is studied. Firstly, the line flow difference of the lines in a non-DER area for the DER and non-DER scenario is captured. The most significant lines of the non-DER area are identified based on the number of hours a line experiences a line flow difference exceeding a predefined threshold. Optimization is conducted to determine the additional battery capacity needed at each DER bus to limit the line flows of the identified significant lines. The results demonstrate that utilizing battery energy storage as ancillary services is an effective strategy for mitigating line flow impacts which in turn reduces the revenue loss for the transmission owner.

Wichita State University (US)
Affordable and clean energy
Openalex Percentile: Top 77%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.