Grid-Forming Inverter-Dominated Power System with Stability Under Large Disturbances

The future inverter-dominated power systems must have a sufficient percentage of Grid-forming (GFM) inverters to support the necessary services of the power system. Among the important services is the performance of inverters and system during large disturbances, especially feeding loads with complex dynamics. On the other hand, the performance of GFM inverters under large disturbances in high IBR-penetration power systems with dynamic loads (such as induction motor loads) has not been sufficiently investigated. In this study, we propose a GFM inverter model and a test system with up to 100% IBR penetration. The performance of the proposed GFM inverter model under large disturbances is evaluated with the test system. The large disturbances include loss of synchronous generator (SG) and starting of a large induction motor (load change) during normal operation. The simulation results showed the proposed GFM inverter model maintains the voltage stability of the 100<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">%</sup> IBR-penetration system under these disturbances.

Authors

Institutions

Publication Details

Published
2024-10-13
DOI
https://doi.org/10.1109/naps61145.2024.10741668
Citations
1
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Grid-Forming Inverter-Dominated Power System with Stability Under Large Disturbances

Siyao Cai, A. P. Sakis Meliopoulos, Zhengrong Chen, Dayou Lu et al.
1 citations
High-Voltage Power Transmission Systems
0.21
article

Grid-Forming Inverter-Dominated Power System with Stability Under Large Disturbances

Siyao Cai, A. P. Sakis Meliopoulos, Zhengrong Chen, Dayou Lu, Syed Sohail Feroz Syed Afroz
article en
1 citations

Abstract

The future inverter-dominated power systems must have a sufficient percentage of Grid-forming (GFM) inverters to support the necessary services of the power system. Among the important services is the performance of inverters and system during large disturbances, especially feeding loads with complex dynamics. On the other hand, the performance of GFM inverters under large disturbances in high IBR-penetration power systems with dynamic loads (such as induction motor loads) has not been sufficiently investigated. In this study, we propose a GFM inverter model and a test system with up to 100% IBR penetration. The performance of the proposed GFM inverter model under large disturbances is evaluated with the test system. The large disturbances include loss of synchronous generator (SG) and starting of a large induction motor (load change) during normal operation. The simulation results showed the proposed GFM inverter model maintains the voltage stability of the 100<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">%</sup> IBR-penetration system under these disturbances.

Georgia Institute of Technology (US)
Affordable and clean energy
Openalex Percentile: Top 46%
High-Voltage Power Transmission Systems
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.