Investigating the Effects of Improved Structural Design on Energy Yield in a Real Solar Farm

This study presents a comprehensive analysis of a 150-kW solar farm to optimize solar yield through improved structural design. Using the System Advisor Model (SAM 2023.12.17), a predictive framework was developed to characterize the behavior of the existing power plant and facilitate its evaluation. The model's accuracy was validated with actual plant data. Parametric analyses compared the current fixed-rack system with the proposed 1-axis tracking system. The fixed-rack system produced 72,715 kWh of annual AC energy in the first year, while the 1-axis system generated 89,594 kWh. Correspondingly, annual cost savings improved from $13,863 to $16,856. The 1-axis detailed ‘PV-Battery’ model revealed unparalleled advantages. This model achieved annual cost savings of $16,856, significant system equity appreciation, and a reduced simple payback period of 13.2 years from 15.8 years in the fixed-axis system. These findings underscore the substantial performance and financial benefits of the 1-axis tracking system over the existing fixed-axis configuration.

Authors

Institutions

Publication Details

Published
2024-10-13
DOI
https://doi.org/10.1109/naps61145.2024.10741636
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigating the Effects of Improved Structural Design on Energy Yield in a Real Solar Farm

Stephen Bayne, Argenis Bilbao, Olatunji Adeyanju, Manohar Chamana et al.
Building Energy and Comfort Optimization
article

Investigating the Effects of Improved Structural Design on Energy Yield in a Real Solar Farm

Stephen Bayne, Argenis Bilbao, Olatunji Adeyanju, Manohar Chamana, Agboola Benjamin Alao
article en

Abstract

This study presents a comprehensive analysis of a 150-kW solar farm to optimize solar yield through improved structural design. Using the System Advisor Model (SAM 2023.12.17), a predictive framework was developed to characterize the behavior of the existing power plant and facilitate its evaluation. The model's accuracy was validated with actual plant data. Parametric analyses compared the current fixed-rack system with the proposed 1-axis tracking system. The fixed-rack system produced 72,715 kWh of annual AC energy in the first year, while the 1-axis system generated 89,594 kWh. Correspondingly, annual cost savings improved from $13,863 to $16,856. The 1-axis detailed ‘PV-Battery’ model revealed unparalleled advantages. This model achieved annual cost savings of $16,856, significant system equity appreciation, and a reduced simple payback period of 13.2 years from 15.8 years in the fixed-axis system. These findings underscore the substantial performance and financial benefits of the 1-axis tracking system over the existing fixed-axis configuration.

Texas Tech University (US)
Affordable and clean energy
Openalex Percentile: Top 79%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.