A Phantom-Free Approach for Estimating the Backscatter Coefficient of Aggregated Red Blood Cells Applied to COVID-19 Patients

The ultrasound backscatter coefficient (BSC) is a frequency-dependent quantity intrinsic to biological tissues that can be recovered from backscattered radio frequency (RF) signals, granted acquisitions on a reference phantom (RP) are available under the same system's settings. A phantom-free (PF) BSC estimation method is proposed based on Gaussian-shaped approximation of the point spread function (PSF) (electronics and piezoelectric characteristics of the scanner's probe) and the effective medium theory combined with the structure factor model (EMTSFM), albeit the proposed approach is amenable to other models. Meanwhile, the total attenuation due to intervening tissues is refined from its theoretical value, which is based on reported average behaviors of tissues, while allowing correction for diffraction due to the probe's geometry. The RP method adapted to a similar approach except for the Gaussian approximation is also presented. The proposed PF and RP methods were compared on ten COVID-19 positive patients and 12 control subjects with measures on femoral veins and arteries. In this context, red blood cells (RBCs) are viewed as scatterers that form aggregates increasing the backscatter under the COVID-19 inflammatory condition. The considered model comprises five parameters, including the mean aggregate size estimated according to the polydispersity of aggregates' radii, and anisotropy of their shape. The mean aggregate size over the two proposed methods presented an intraclass correlation coefficient (ICC) of 0.964 for consistency. The aggregate size presented a significant difference between the two groups with either two methods, despite the confounding effect of the maximum Doppler velocity within the blood vessel and its diameter.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Published
2024-11-07
DOI
https://doi.org/10.1109/tuffc.2024.3493602
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Phantom-Free Approach for Estimating the Backscatter Coefficient of Aggregated Red Blood Cells Applied to COVID-19 Patients

Martin Girard, Boris Chayer, Madéleine Durand, Louise Allard et al.
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Photoacoustic and Ultrasonic Imaging
article

A Phantom-Free Approach for Estimating the Backscatter Coefficient of Aggregated Red Blood Cells Applied to COVID-19 Patients

Martin Girard, Boris Chayer, Madéleine Durand, Louise Allard, William Beaubien–Souligny, Guy Cloutier, François Destrempes, Marie‐Hélène Roy Cardinal, Hassan Rivaz
article en

Abstract

The ultrasound backscatter coefficient (BSC) is a frequency-dependent quantity intrinsic to biological tissues that can be recovered from backscattered radio frequency (RF) signals, granted acquisitions on a reference phantom (RP) are available under the same system's settings. A phantom-free (PF) BSC estimation method is proposed based on Gaussian-shaped approximation of the point spread function (PSF) (electronics and piezoelectric characteristics of the scanner's probe) and the effective medium theory combined with the structure factor model (EMTSFM), albeit the proposed approach is amenable to other models. Meanwhile, the total attenuation due to intervening tissues is refined from its theoretical value, which is based on reported average behaviors of tissues, while allowing correction for diffraction due to the probe's geometry. The RP method adapted to a similar approach except for the Gaussian approximation is also presented. The proposed PF and RP methods were compared on ten COVID-19 positive patients and 12 control subjects with measures on femoral veins and arteries. In this context, red blood cells (RBCs) are viewed as scatterers that form aggregates increasing the backscatter under the COVID-19 inflammatory condition. The considered model comprises five parameters, including the mean aggregate size estimated according to the polydispersity of aggregates' radii, and anisotropy of their shape. The mean aggregate size over the two proposed methods presented an intraclass correlation coefficient (ICC) of 0.964 for consistency. The aggregate size presented a significant difference between the two groups with either two methods, despite the confounding effect of the maximum Doppler velocity within the blood vessel and its diameter.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency ControlVol. 71(12: Breaking the Resolution)
Concordia University (CA), Université de Montréal (CA)
Natural Sciences and Engineering Research Council of Canada
Openalex Percentile: Top 82%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.