Detection-Triggered Recursive Impact Mitigation Against Secondary False Data Injection Attacks in Cyber-Physical Microgrid

The cybersecurity of microgrid has received widespread attentions due to the frequently reported attack accidents against distributed energy resource (DER) manufactures. Numerous impact mitigation schemes have been proposed to reduce or eliminate the impacts of false data injection attacks (FDIAs). Nevertheless, the existing methods either requires at least one neighboring trustworthy agent or may bring in unacceptable cost burdens. This paper aims to propose a detection-triggered recursive impact mitigation scheme that can timely and precisely counter the secondary FDIAs (SFDIAs) against the communication links among DERs. Once triggering attack alarms, the power line current readings will be utilised to observe the voltage bias injections through the physical interconnections among DERs, based on which the current bias injections can be recursively reconstructed from the residuals generated by unknown input observers (UIOs). The attack impacts are eliminated by subtracting the reconstructed bias from the incoming compromised data. The proposed mitigation method can work even in the worst case where all communication links are under SFDIAs and only require extra current sensors. The bias reconstruction performance under initial errors and system noises is theoretically analysed and the reconstruction error is proved to be bounded regardless of the electrical parameters. To avoid deploying current sensors on all power lines, a cost-effective deployment strategy is presented to secure a spanning tree set of communication links that can guarantee the secondary control performance. Extensive validation studies are conducted in MATLAB/Simulink and cyber-physical microgrid testbeds to validate the proposed method’s effectiveness against single/multiple and continuous/discrete SFDIAs.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Smart Grid
Published
2024-11-07
DOI
https://doi.org/10.1109/tsg.2024.3493754
Citations
13
Primary Topic
Smart Grid Security and Resilience
Type
article
Field-Weighted Citation Impact
4.27
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection-Triggered Recursive Impact Mitigation Against Secondary False Data Injection Attacks in Cyber-Physical Microgrid

Mengxiang Liu, Zhenyong Zhang, Xin Zhang, Ruilong Deng et al.
13 citations
IEEE Transactions on Smart Grid
Smart Grid Security and Resilience
4.27
article

Detection-Triggered Recursive Impact Mitigation Against Secondary False Data Injection Attacks in Cyber-Physical Microgrid

Mengxiang Liu, Zhenyong Zhang, Xin Zhang, Ruilong Deng, Rui Zhang, Zhuoran Zhou
article en
13 citations

Abstract

The cybersecurity of microgrid has received widespread attentions due to the frequently reported attack accidents against distributed energy resource (DER) manufactures. Numerous impact mitigation schemes have been proposed to reduce or eliminate the impacts of false data injection attacks (FDIAs). Nevertheless, the existing methods either requires at least one neighboring trustworthy agent or may bring in unacceptable cost burdens. This paper aims to propose a detection-triggered recursive impact mitigation scheme that can timely and precisely counter the secondary FDIAs (SFDIAs) against the communication links among DERs. Once triggering attack alarms, the power line current readings will be utilised to observe the voltage bias injections through the physical interconnections among DERs, based on which the current bias injections can be recursively reconstructed from the residuals generated by unknown input observers (UIOs). The attack impacts are eliminated by subtracting the reconstructed bias from the incoming compromised data. The proposed mitigation method can work even in the worst case where all communication links are under SFDIAs and only require extra current sensors. The bias reconstruction performance under initial errors and system noises is theoretically analysed and the reconstruction error is proved to be bounded regardless of the electrical parameters. To avoid deploying current sensors on all power lines, a cost-effective deployment strategy is presented to secure a spanning tree set of communication links that can guarantee the secondary control performance. Extensive validation studies are conducted in MATLAB/Simulink and cyber-physical microgrid testbeds to validate the proposed method’s effectiveness against single/multiple and continuous/discrete SFDIAs.

IEEE Transactions on Smart GridVol. 16(2)
National University System (US), State Key Laboratory of Industrial Control Technology (CN), University of Sheffield (GB)
Climate action
Openalex Percentile: Top 5%
Smart Grid Security and Resilience
4.27
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.