Velocity Estimation beyond Nyquist Limit for Pulse Doppler Radars Using Pulse-Compressed Signals Correlated with Divided Reference Signals

We propose seven velocity-estimation methods for fast moving targets beyond the Nyquist-limit velocity for pulse Doppler radars. The Doppler-shift frequency beyond the Nyquist limit, which equals one-half the pulse-repetition frequency, cannot be correctly measured as the frequency is folded back within the Nyquist interval. Our methods use pulse compression with divided reference signals of varying center frequencies to detect the difference among the Doppler-shift frequencies of the pulse-compressed signals and increase sensitivity through signal integration, all without modifying the transmitted signals. These methods are either grid-search-type or Newton-type methods, each possessing distinct characteristics. The Cramér-Rao lower bounds on the variance of estimated velocity are derived, and the upper bounds on the probability of correct ambiguity resolution are shown. The results of our numerical simulation indicate that our methods can estimate target velocity beyond the Nyquist-limit velocity and that the method of independently estimating the Doppler frequencies at both end parts of the signal bandwidth and estimating the target velocity from the difference exhibits a lower decrease than the other methods regarding the success probability of Doppler ambiguity resolution even for high target velocities. We also confirmed that the upper bounds closely match the probability of corresponding methods for when the target velocity is lower than several times the Nyquist velocity and the signal-to-noise ratio on the range-Doppler map is above approximately 20 dB.

Authors

Institutions

Publication Details

Journal
IEICE Transactions on Communications
Published
2024-11-07
DOI
https://doi.org/10.23919/transcom.2024ebp3054
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Velocity Estimation beyond Nyquist Limit for Pulse Doppler Radars Using Pulse-Compressed Signals Correlated with Divided Reference Signals

Koji Nishimura, Takafumi Nagano, Hiroyuki Hashiguchi, Tadao FUKUTA
IEICE Transactions on Communications
Non-Invasive Vital Sign Monitoring
article

Velocity Estimation beyond Nyquist Limit for Pulse Doppler Radars Using Pulse-Compressed Signals Correlated with Divided Reference Signals

Koji Nishimura, Takafumi Nagano, Hiroyuki Hashiguchi, Tadao FUKUTA
article en

Abstract

We propose seven velocity-estimation methods for fast moving targets beyond the Nyquist-limit velocity for pulse Doppler radars. The Doppler-shift frequency beyond the Nyquist limit, which equals one-half the pulse-repetition frequency, cannot be correctly measured as the frequency is folded back within the Nyquist interval. Our methods use pulse compression with divided reference signals of varying center frequencies to detect the difference among the Doppler-shift frequencies of the pulse-compressed signals and increase sensitivity through signal integration, all without modifying the transmitted signals. These methods are either grid-search-type or Newton-type methods, each possessing distinct characteristics. The Cramér-Rao lower bounds on the variance of estimated velocity are derived, and the upper bounds on the probability of correct ambiguity resolution are shown. The results of our numerical simulation indicate that our methods can estimate target velocity beyond the Nyquist-limit velocity and that the method of independently estimating the Doppler frequencies at both end parts of the signal bandwidth and estimating the target velocity from the difference exhibits a lower decrease than the other methods regarding the success probability of Doppler ambiguity resolution even for high target velocities. We also confirmed that the upper bounds closely match the probability of corresponding methods for when the target velocity is lower than several times the Nyquist velocity and the signal-to-noise ratio on the range-Doppler map is above approximately 20 dB.

IEICE Transactions on CommunicationsVol. E108-B(4)
Kyoto University (JP), Mitsubishi Electric (Japan) (JP), Research Institute for Sustainable Humanosphere
Affordable and clean energy
Openalex Percentile: Top 82%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Velocity Estimation beyond Nyquist Limit for Pulse Doppler Radars Using Pulse-Compressed Signals Correlated with Divided Reference Signals — Koji Nishimura, Takafumi Nagano, et al. · IEICE Transactions on Communications (2024) | TGRS Research Map | TGRS