Performance and safety evaluation of a cold ablation robot-guided laser osteotome (CARLO) in 28 midface osteotomies

The CARLO (cold ablation robot-guided laser osteotome) is a compact device with integrated multiple sensory, steering and safety checking elements. A multi-center study was performed to evaluate the CARLO device for the linear part of midface osteotomy in 28 patients. Feasibility, success rate, safety, performance and experience of the surgeons were assessed and evaluated. All 28 procedures were completed with CARLO without falling back to the conventional methods, giving a technical success rate of 100%. For 27 (96%) cases, procedural success was achieved with cutting lines deviation less than 2 mm. For 25 procedures, the CARLO-cutting was conducted smoothly. In the other 3 cases, some minor difficulties related to the reference markers were reported. For 18 procedures, no change for the cutting path was necessary. For the other 10 cases, cut path was adapted. Intraoperative re-planning was possible, easy and quick without significant delay of the procedures. No CARLO-related adverse events were recorded. Especially, there was no unexpected and unusual bleeding during the CARLO-conducted osteotomy. The time needed for the registration ranged from 1 to 12 min (median = 4). The CARLO-cutting lasted for 5 to 21 min (median = 7). The present study demonstrated feasibility, simplicity, safety, reliability and accuracy of CARLO for the linear part of midface osteotomy.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-11-07
DOI
https://doi.org/10.1038/s41598-024-68557-7
Citations
5
Primary Topic
Laser Applications in Dentistry and Medicine
Type
article
Field-Weighted Citation Impact
2.02
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance and safety evaluation of a cold ablation robot-guided laser osteotome (CARLO) in 28 midface osteotomies

Shih-Jan Chin, Lan Kluwe, Sibylle Hirsch, Daniel Holzinger et al.
5 citations
Scientific Reports
Laser Applications in Dentistry and Medicine
2.02
article

Performance and safety evaluation of a cold ablation robot-guided laser osteotome (CARLO) in 28 midface osteotomies

Shih-Jan Chin, Lan Kluwe, Sibylle Hirsch, Daniel Holzinger, Robert Köhnke, Marta M. Morawska, Jan Wolff, P. Juergens, Ralf Smeets, Kurt Schicho, A. Müller, Alexandre T. Assaf, Tobias Wilken, G. Millesi, Katja Helmbold
article en
5 citations

Abstract

The CARLO (cold ablation robot-guided laser osteotome) is a compact device with integrated multiple sensory, steering and safety checking elements. A multi-center study was performed to evaluate the CARLO device for the linear part of midface osteotomy in 28 patients. Feasibility, success rate, safety, performance and experience of the surgeons were assessed and evaluated. All 28 procedures were completed with CARLO without falling back to the conventional methods, giving a technical success rate of 100%. For 27 (96%) cases, procedural success was achieved with cutting lines deviation less than 2 mm. For 25 procedures, the CARLO-cutting was conducted smoothly. In the other 3 cases, some minor difficulties related to the reference markers were reported. For 18 procedures, no change for the cutting path was necessary. For the other 10 cases, cut path was adapted. Intraoperative re-planning was possible, easy and quick without significant delay of the procedures. No CARLO-related adverse events were recorded. Especially, there was no unexpected and unusual bleeding during the CARLO-conducted osteotomy. The time needed for the registration ranged from 1 to 12 min (median = 4). The CARLO-cutting lasted for 5 to 21 min (median = 7). The present study demonstrated feasibility, simplicity, safety, reliability and accuracy of CARLO for the linear part of midface osteotomy.

Scientific ReportsVol. 14(1)
Universität Hamburg (DE), Aarhus University (DK), University Hospital of Basel (CH), University Medical Center Hamburg-Eppendorf (DE), National Medical Research Center of Dentistry and Maxillofacial Surgery (RU), Medical University of Vienna (AT)
Openalex Percentile: Top 13%
Laser Applications in Dentistry and Medicine
2.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines