Estimation and analysis of S values for <sup>131</sup>I using paediatric mesh type reference computational phantoms

This study examines the effect of paediatric mesh-type reference computational phantoms on organ<i>S</i>values resulting from radioiodine (<sup>131</sup>I) intake. Using Geant4, we estimated<sup>131</sup>I<i>S</i>values for 30 radiosensitive target tissues due to emission from the thyroid (Target ← Thyroid) in these phantoms. Our results show that<i>S</i>values differ between male and female phantoms of the same age and<i>S</i>values also decrease as phantom age increases. The male-to-female<i>S</i>value ratio typically varies within 10%, with larger differences observed for the esophagus, extra-thoracic regions, muscles, bladder, and sex organs. On average,<i>S</i>values for mesh phantoms are approximately 17% higher than those for voxel phantoms, with larger discrepancies for organs remodelled separately in mesh phantoms. The study provides organ<i>S</i>values for the paediatric population due to<sup>131</sup>I exposure from the thyroid, based on the reference mesh-type computational phantoms, enhancing organ dose estimation in emergency situations and during radioiodine treatment.

Authors

Institutions

Publication Details

Journal
Journal of Radiological Protection
Published
2024-11-07
DOI
https://doi.org/10.1088/1361-6498/ad8fb8
Citations
1
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Estimation and analysis of S values for 131I using paediatric mesh type reference computational phantoms

H. K. Patni, D. K. Akar, Pramilla D. Sawant, Pradeep Kumar Singh
1 citations
Journal of Radiological Protection
Medical Imaging Techniques and Applications
0.40
article

Estimation and analysis of S values for 131I using paediatric mesh type reference computational phantoms

H. K. Patni, D. K. Akar, Pramilla D. Sawant, Pradeep Kumar Singh
article en
1 citations

Abstract

This study examines the effect of paediatric mesh-type reference computational phantoms on organ<i>S</i>values resulting from radioiodine (<sup>131</sup>I) intake. Using Geant4, we estimated<sup>131</sup>I<i>S</i>values for 30 radiosensitive target tissues due to emission from the thyroid (Target ← Thyroid) in these phantoms. Our results show that<i>S</i>values differ between male and female phantoms of the same age and<i>S</i>values also decrease as phantom age increases. The male-to-female<i>S</i>value ratio typically varies within 10%, with larger differences observed for the esophagus, extra-thoracic regions, muscles, bladder, and sex organs. On average,<i>S</i>values for mesh phantoms are approximately 17% higher than those for voxel phantoms, with larger discrepancies for organs remodelled separately in mesh phantoms. The study provides organ<i>S</i>values for the paediatric population due to<sup>131</sup>I exposure from the thyroid, based on the reference mesh-type computational phantoms, enhancing organ dose estimation in emergency situations and during radioiodine treatment.

Journal of Radiological ProtectionVol. 44(4)
Bhabha Atomic Research Centre (IN)
Openalex Percentile: Top 33%
Medical Imaging Techniques and Applications
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Estimation and analysis of S values for <sup>131</sup>I using paediatric mesh type reference computational phantoms — H. K. Patni, D. K. Akar, et al. · Journal of Radiological Protection (2024) | TGRS Research Map | TGRS