Fast Analysis of Humic Acid in Mud and Water Samples

A broad spectrum of pharmacological activity of mud is related to humic acid, creating a need for fast reliable methods for its assay in mud and water samples. This paper proposes an electroanalytical method for the determination of humic acid content using a stochastic sensor, a method that does not involve the extraction of active ingredients prior to the determination. The method has proven to be a very good choice for the analysis as no sample processing is needed, the sample matrix does not influence the analysis results, and reliable quantitative and qualitative analyses can be performed. High sensitivity (1.61 × 10 9 s −1 g −1 ml) and very low limit of determination (1 × 10 −18 g ml −1 ) were recorded. Recoveries higher than 95.00% of humic acid, with percentages of RSD lower than 1.00 determined, when the stochastic sensor was used for the electroanalysis of humic acid in mud.

Authors

Publication Details

Journal
Journal of The Electrochemical Society
Published
2024-11-01
DOI
https://doi.org/10.1149/1945-7111/ad8fd6
Primary Topic
Humic Substances and Bio-Organic Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fast Analysis of Humic Acid in Mud and Water Samples

Catalina Cioates Negut, Raluca‐Ioana Stefan‐van Staden, George A. Stanciu, Andreea Elena Sandu Dorneanu
Journal of The Electrochemical Society
Humic Substances and Bio-Organic Studies
article

Fast Analysis of Humic Acid in Mud and Water Samples

Catalina Cioates Negut, Raluca‐Ioana Stefan‐van Staden, George A. Stanciu, Andreea Elena Sandu Dorneanu
article en

Abstract

A broad spectrum of pharmacological activity of mud is related to humic acid, creating a need for fast reliable methods for its assay in mud and water samples. This paper proposes an electroanalytical method for the determination of humic acid content using a stochastic sensor, a method that does not involve the extraction of active ingredients prior to the determination. The method has proven to be a very good choice for the analysis as no sample processing is needed, the sample matrix does not influence the analysis results, and reliable quantitative and qualitative analyses can be performed. High sensitivity (1.61 × 10 9 s −1 g −1 ml) and very low limit of determination (1 × 10 −18 g ml −1 ) were recorded. Recoveries higher than 95.00% of humic acid, with percentages of RSD lower than 1.00 determined, when the stochastic sensor was used for the electroanalysis of humic acid in mud.

Journal of The Electrochemical SocietyVol. 171(11)
Openalex Percentile: Top 74%
Humic Substances and Bio-Organic Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.