A Novel Anthropometric Phantom for Rapid Radiological Triage: A Quick Sort Triage Solution

Rapidly identifying individuals who have received internal radiation exposure above action guidelines is crucial for mitigating health risks and addressing public concerns immediately following a radiological event involving the dispersal of radioactive materials. This study describes a novel triage method using a conventional Geiger-Mueller (GM) detector to select those individuals from the large group of persons who may have received an intake of radioactive material at levels corresponding to one Clinical Decision Guide (CDG). The triage method involves placing a portable GM detector against the lower anterior torso of a sitting person as they bend over to surround the detector with their body. The response of the GM detector is evaluated using a new, specially designed anthropometric phantom that simulates combined tissues of the lower thorax and gastrointestinal (GI) tract and is fabricated with a tissue substitute material that matches the overall radiological properties of human tissue present in this body region. The phantom has four separate layers of tissue substitute material with ports to accommodate a single GM detector at the center and one or more sealed radioactive sources that can be arranged to characterize the detector response for a variety of source distributions, including a "hot spot." In this study, the response of a Ludlum Model 133-4 GM detector was evaluated using sealed sources of 232 Th and 137 Cs to determine the measurement efficiency for a quantity of activity present in the abdomen within a few hours post-intake equivalent to 1 CDG. Results demonstrate that the Quick Sort triage procedure using a single GM detector placed against the abdomen of a person can reliably detect internal deposition resulting from an intake equivalent to 1 CDG for 232 Th or a significantly lower activity of 137 Cs within a few hours following a radiological incident. The evaluation was performed over a wide range of photon energies, so the Quick Sort triage procedure is expected to be suitable for most fission products distributed uniformly within the abdomen or as a single "hot spot."

Authors

Institutions

Publication Details

Journal
Health Physics
Published
2024-11-06
DOI
https://doi.org/10.1097/hp.0000000000001887
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Anthropometric Phantom for Rapid Radiological Triage: A Quick Sort Triage Solution

Henry B. Spitz, H. Datz, O. Aviv
Health Physics
Radiation Dose and Imaging
article

A Novel Anthropometric Phantom for Rapid Radiological Triage: A Quick Sort Triage Solution

Henry B. Spitz, H. Datz, O. Aviv
article en

Abstract

Rapidly identifying individuals who have received internal radiation exposure above action guidelines is crucial for mitigating health risks and addressing public concerns immediately following a radiological event involving the dispersal of radioactive materials. This study describes a novel triage method using a conventional Geiger-Mueller (GM) detector to select those individuals from the large group of persons who may have received an intake of radioactive material at levels corresponding to one Clinical Decision Guide (CDG). The triage method involves placing a portable GM detector against the lower anterior torso of a sitting person as they bend over to surround the detector with their body. The response of the GM detector is evaluated using a new, specially designed anthropometric phantom that simulates combined tissues of the lower thorax and gastrointestinal (GI) tract and is fabricated with a tissue substitute material that matches the overall radiological properties of human tissue present in this body region. The phantom has four separate layers of tissue substitute material with ports to accommodate a single GM detector at the center and one or more sealed radioactive sources that can be arranged to characterize the detector response for a variety of source distributions, including a "hot spot." In this study, the response of a Ludlum Model 133-4 GM detector was evaluated using sealed sources of 232 Th and 137 Cs to determine the measurement efficiency for a quantity of activity present in the abdomen within a few hours post-intake equivalent to 1 CDG. Results demonstrate that the Quick Sort triage procedure using a single GM detector placed against the abdomen of a person can reliably detect internal deposition resulting from an intake equivalent to 1 CDG for 232 Th or a significantly lower activity of 137 Cs within a few hours following a radiological incident. The evaluation was performed over a wide range of photon energies, so the Quick Sort triage procedure is expected to be suitable for most fission products distributed uniformly within the abdomen or as a single "hot spot."

Health PhysicsVol. 128(2)
Israel Atomic Energy Commission (IL), Soreq Nuclear Research Center, University of Cincinnati (US)
Good health and well-being
Openalex Percentile: Top 67%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.