Optimization of cooling system parameters with temperature field of mass concrete during hydration

Embedded cooling pipe system is regarded as the primary means in mass concrete to control the temperature. The effects of three factors are investigated on the thermal field of mass concrete by the combination of measurement, theoretical analyse and numerical simulation in this paper, including cooling pipe spacing, pipe diameter and pipe arrangement. The results demonstrate that the peak temperature is reduced by the increase in both of the pipe distance and pipe diameter. The peak temperature is measured to decrease from 1°C to 3°C on the monitoring points, with additional 0.5 m of pipe spacing or 10 mm of pipe diameter. The serious influence is conducted by the pipe diameter on the temperature difference, and the selection of cooling pipe diameter is considered to balance multiple problems in the project necessarily. The serpentine arrangement is more widely used for better cooling and construction in the comparison of the circular arrangement. The results on the optimization of cooling system are utilized for the project to control the hydration heat accurately and reduce or even prevent the generation of cracks.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2024-11-07
DOI
https://doi.org/10.1016/j.csite.2024.105456
Citations
7
Primary Topic
Concrete and Cement Materials Research
Type
article
Field-Weighted Citation Impact
1.83
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of cooling system parameters with temperature field of mass concrete during hydration

Xiangwei Hao, Songqing Wang, Yinuo Zhang, Shijing He et al.
7 citations
Case Studies in Thermal Engineering
Concrete and Cement Materials Research
1.83
article

Optimization of cooling system parameters with temperature field of mass concrete during hydration

Xiangwei Hao, Songqing Wang, Yinuo Zhang, Shijing He, Jianan Duan
article en
7 citations

Abstract

Embedded cooling pipe system is regarded as the primary means in mass concrete to control the temperature. The effects of three factors are investigated on the thermal field of mass concrete by the combination of measurement, theoretical analyse and numerical simulation in this paper, including cooling pipe spacing, pipe diameter and pipe arrangement. The results demonstrate that the peak temperature is reduced by the increase in both of the pipe distance and pipe diameter. The peak temperature is measured to decrease from 1°C to 3°C on the monitoring points, with additional 0.5 m of pipe spacing or 10 mm of pipe diameter. The serious influence is conducted by the pipe diameter on the temperature difference, and the selection of cooling pipe diameter is considered to balance multiple problems in the project necessarily. The serpentine arrangement is more widely used for better cooling and construction in the comparison of the circular arrangement. The results on the optimization of cooling system are utilized for the project to control the hydration heat accurately and reduce or even prevent the generation of cracks.

Case Studies in Thermal EngineeringVol. 64
Northeast Forestry University (CN)
Openalex Percentile: Top 16%
Concrete and Cement Materials Research
1.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.