Absolute depth-resolved optic axis measurement with catheter-based polarization sensitive optical coherence tomography

Imaging depth-resolved birefringence and optic axis orientation with polarization sensitive optical coherence tomography (PS-OCT) unveils details of tissue structure and organization that can be of high pathophysiologic, mechanistic, and diagnostic value. For catheter-based PS-OCT, the dynamic rotation of the fiber optic probe, in addition to the polarization effects of the system components, complicates the reliable and robust reconstruction of the sample's optic axis orientation. Addressing this issue, we present a new method for the reconstruction of absolute depth-resolved optic axis orientation in catheter-based PS-OCT by using the intrinsic retardance of the protecting catheter sheath as a stable guide star signal. Throughout the paper, we rigorously inspect the retardance and optic axis orientation of the sheath and validate our method by imaging a birefringent phantom with known optic axis orientation. Reconstructing the optic axis orientation of the phantom, placed at different locations around the catheter, we measured an average absolute deviation (AAD) for the mean optic axis orientation over cross-sectional images of 3.28°, even with significant bending stress on the catheter. This corresponds to an almost three-fold improvement compared to our earlier method (optic axis AAD of 9.41°). We finally highlight the capability of our reconstruction with stereotactic catheter-based PS-OCT of a fresh sheep brain.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2024-11-07
DOI
https://doi.org/10.1364/boe.538560
Citations
2
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Absolute depth-resolved optic axis measurement with catheter-based polarization sensitive optical coherence tomography

Martin Parent, Martin Villiger, Lida P. Hariri, Jaeyul Lee et al.
2 citations
Biomedical Optics Express
Optical Coherence Tomography Applications
0.37
article

Absolute depth-resolved optic axis measurement with catheter-based polarization sensitive optical coherence tomography

Martin Parent, Martin Villiger, Lida P. Hariri, Jaeyul Lee, Shadi Masoumi, G. Jones, Brett E. Bouma, Daniel Côté, Mireille Quémener
article en
2 citations

Abstract

Imaging depth-resolved birefringence and optic axis orientation with polarization sensitive optical coherence tomography (PS-OCT) unveils details of tissue structure and organization that can be of high pathophysiologic, mechanistic, and diagnostic value. For catheter-based PS-OCT, the dynamic rotation of the fiber optic probe, in addition to the polarization effects of the system components, complicates the reliable and robust reconstruction of the sample's optic axis orientation. Addressing this issue, we present a new method for the reconstruction of absolute depth-resolved optic axis orientation in catheter-based PS-OCT by using the intrinsic retardance of the protecting catheter sheath as a stable guide star signal. Throughout the paper, we rigorously inspect the retardance and optic axis orientation of the sheath and validate our method by imaging a birefringent phantom with known optic axis orientation. Reconstructing the optic axis orientation of the phantom, placed at different locations around the catheter, we measured an average absolute deviation (AAD) for the mean optic axis orientation over cross-sectional images of 3.28°, even with significant bending stress on the catheter. This corresponds to an almost three-fold improvement compared to our earlier method (optic axis AAD of 9.41°). We finally highlight the capability of our reconstruction with stereotactic catheter-based PS-OCT of a fresh sheep brain.

Biomedical Optics ExpressVol. 15(12)
Harvard University (US), Massachusetts General Hospital (US), Université Laval (CA), Massachusetts Institute of Technology (US)
Massachusetts Institute of Technology, Terumo, Natural Sciences and Engineering Research Council of Canada, National Heart, Lung, and Blood Institute, National Institute of Biomedical Imaging and Bioengineering
Affordable and clean energy
Openalex Percentile: Top 42%
Optical Coherence Tomography Applications
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.