Modified Use of the Component Method to Get More Realistic Force Distribution in Joints of Steel Structures

According to the EN 1993-1-8 Standard, the moment resistance of end-plated connections can be calculated with the use of the component method. In this, a pair-of-force defines the moment resistance. The magnitude and the location of the compression force can be accurately identified. The tension force part is usually the resultant of parallel forces appearing in line with the bolt rows. Following the rules of manual calculation and using a mechanical finite element model, where each component is modelled with spring elements, in some—easily identifiable—cases, leads to different force distribution. The simplifications defined in the Standard provide a longer arm for the same force, and because of this, larger moment resistance at the expense of safety. In this work, an alternative calculation method will be presented that provides the same force values in each bolt row, as the mechanical model of the connection, without constructing the finite element model.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2024-11-07
DOI
https://doi.org/10.3390/buildings14113553
Citations
1
Primary Topic
Mechanical and Thermal Properties Analysis
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modified Use of the Component Method to Get More Realistic Force Distribution in Joints of Steel Structures

Imre Kovács, László Radnay
1 citations
Buildings
Mechanical and Thermal Properties Analysis
0.21
article

Modified Use of the Component Method to Get More Realistic Force Distribution in Joints of Steel Structures

Imre Kovács, László Radnay
article en
1 citations

Abstract

According to the EN 1993-1-8 Standard, the moment resistance of end-plated connections can be calculated with the use of the component method. In this, a pair-of-force defines the moment resistance. The magnitude and the location of the compression force can be accurately identified. The tension force part is usually the resultant of parallel forces appearing in line with the bolt rows. Following the rules of manual calculation and using a mechanical finite element model, where each component is modelled with spring elements, in some—easily identifiable—cases, leads to different force distribution. The simplifications defined in the Standard provide a longer arm for the same force, and because of this, larger moment resistance at the expense of safety. In this work, an alternative calculation method will be presented that provides the same force values in each bolt row, as the mechanical model of the connection, without constructing the finite element model.

BuildingsVol. 14(11)
University of Debrecen (HU)
Debreceni Egyetem
Sustainable cities and communities
Openalex Percentile: Top 50%
Mechanical and Thermal Properties Analysis
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Modified Use of the Component Method to Get More Realistic Force Distribution in Joints of Steel Structures — Imre Kovács, László Radnay · Buildings (2024) | TGRS Research Map | TGRS