Accuracy of intraocular lens power calculation in patients with endothelial dystrophy without edema
The prediction accuracy of IOL power calculation in patients with ED was found comparable both between formulas and in comparison with healthy controls. This suggests that in patients with guttate without edema, the IOL power calculations are as effective and accurate as in healthy eyes.
Authors
- Olga Reitblat (ORCID: https://orcid.org/0000-0002-8417-4440)
- Maayan Fradkin
- Ruti Sella (ORCID: https://orcid.org/0000-0002-4748-4685)
- Adi Einan‐Lifshitz (ORCID: https://orcid.org/0000-0002-0556-4898)
- Asaf Shemer (ORCID: https://orcid.org/0000-0002-4366-5438)
- Biana Dubinsky‐Pertzov (ORCID: https://orcid.org/0000-0002-4998-8772)
- Eran Pras
- Francis Simaan (ORCID: https://orcid.org/0009-0003-8116-2676)
Institutions
- Tel Aviv University (IL)
- Rabin Medical Center (IL)
- Assaf Harofeh Medical Center (IL)
Publication Details
- Journal
- Journal of Cataract & Refractive Surgery
- Published
- 2024-11-06
- DOI
- https://doi.org/10.1097/j.jcrs.0000000000001578
- Primary Topic
- Corneal surgery and disorders
- Type
- article
- Field-Weighted Citation Impact
- 0.00