ANALYSIS OF ARTESIAN WATER QUALITY INDICATORS DEPENDING ON THE DEPTH OF THE AQUIFER

The analysis of water samples from artesian well No. 451/D-15 in Turov town (well depth – 333.5 meters) and a well from the agrotown Raduga, Vetkovsky district, Gomel region (well depth – 18 meters) was carried out. The dependence of water quality indicators on the depth of the aquifer was de-tected. The most important quality indicators were established for comparison of experimental samples with the standards of SanPiN 2.1.4.12-23–2006 for consumption in food and with the standards of TPP-1 (thermal power plant) for analysis of possible use of water from wells as a body of the cycle. Based on the obtained data, a comparison of water quality indicators was made and an optimal water treatment plant was selected for further satisfactory use of the well as a source of drinking water, relative to the exceeding parameters.

Authors

Publication Details

Journal
Bulletin Sukhoi State Technical University of Gomel
Published
2024-10-01
DOI
https://doi.org/10.62595/1819-5245-2024-3-45-52
Primary Topic
Water Quality and Pollution Assessment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ANALYSIS OF ARTESIAN WATER QUALITY INDICATORS DEPENDING ON THE DEPTH OF THE AQUIFER

Ekaterina Makeeva, K. A. AGUNOVICH
Bulletin Sukhoi State Technical University of Gomel
Water Quality and Pollution Assessment
article

ANALYSIS OF ARTESIAN WATER QUALITY INDICATORS DEPENDING ON THE DEPTH OF THE AQUIFER

Ekaterina Makeeva, K. A. AGUNOVICH
article en

Abstract

The analysis of water samples from artesian well No. 451/D-15 in Turov town (well depth – 333.5 meters) and a well from the agrotown Raduga, Vetkovsky district, Gomel region (well depth – 18 meters) was carried out. The dependence of water quality indicators on the depth of the aquifer was de-tected. The most important quality indicators were established for comparison of experimental samples with the standards of SanPiN 2.1.4.12-23–2006 for consumption in food and with the standards of TPP-1 (thermal power plant) for analysis of possible use of water from wells as a body of the cycle. Based on the obtained data, a comparison of water quality indicators was made and an optimal water treatment plant was selected for further satisfactory use of the well as a source of drinking water, relative to the exceeding parameters.

Bulletin Sukhoi State Technical University of Gomel(1)
Openalex Percentile: Top 81%
Water Quality and Pollution Assessment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.