Incidence of ventricular arrhythmias after implantable cardioverter-defibrillator implantation or replacement, and driving restriction consequences
Primary prevention patients, such as those who have undergone device replacement, have a low risk of ventricular arrhythmia, which could lead to a reduction in their driving restriction period. Secondary prevention patients experienced a higher risk of recurrent ventricular arrhythmia, supporting the 3-month driving restriction period.
Authors
- Vincent Galand (ORCID: https://orcid.org/0000-0002-2593-6345)
- Nathalie Béhar (ORCID: https://orcid.org/0000-0001-7529-8735)
- Karim Bénali (ORCID: https://orcid.org/0000-0002-7108-3427)
- Thomas Marc
- Philippe Mabo
- Raphaël P. Martins (ORCID: https://orcid.org/0000-0001-5716-6712)
- Dominique Pavin (ORCID: https://orcid.org/0000-0003-2484-450X)
- P Groussin (ORCID: https://orcid.org/0009-0004-8832-9157)
- Joana Brito (ORCID: https://orcid.org/0000-0001-6672-7542)
- Redwane Rakza
- Christophe Leclercq
Institutions
- Inserm (FR)
- Centre Hospitalier Universitaire de Rennes (FR)
- Centre Hospitalier Universitaire de Saint-Étienne (FR)
- Université de Rennes (FR)
Publication Details
- Journal
- Archives of cardiovascular diseases
- Published
- 2024-11-06
- DOI
- https://doi.org/10.1016/j.acvd.2024.10.005
- Citations
- 2
- Primary Topic
- Cardiac pacing and defibrillation studies
- Type
- article
- Field-Weighted Citation Impact
- 0.80