Robust Distributed Load Frequency Control for Multi-Area Power Systems with Photovoltaic and Battery Energy Storage System

The intermittent power generation of renewable energy sources (RESs) interrupts the balance between power generation and demand load due to the increased frequency fluctuation, which challenges the frequency stability analysis and control synthesis of power generation systems. This paper proposes a robust distributed load frequency control (DLFC) scheme for multi-area power systems. Firstly, a multi-area power system is constructed by integrating photovoltaic (PV) and battery energy storage systems (BESSs). Then, by employing the linear matrix inequality (LMI) technique, the sufficient condition capable of ensuring that the proposed controller satisfies H∞ robust performance in the sense of asymptotic stability is derived. Finally, testing is conducted on a four-area renewable power system, and results verify the strong robustness of the proposed controller against load disturbance and intermittence of RESs.

Authors

Institutions

Publication Details

Journal
Energies
Published
2024-11-06
DOI
https://doi.org/10.3390/en17225536
Citations
7
Primary Topic
Frequency Control in Power Systems
Type
article
Field-Weighted Citation Impact
1.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Robust Distributed Load Frequency Control for Multi-Area Power Systems with Photovoltaic and Battery Energy Storage System

Yunrui Lan, Mahesh S. Illindala
7 citations
Energies
Frequency Control in Power Systems
1.46
article

Robust Distributed Load Frequency Control for Multi-Area Power Systems with Photovoltaic and Battery Energy Storage System

Yunrui Lan, Mahesh S. Illindala
article en
7 citations

Abstract

The intermittent power generation of renewable energy sources (RESs) interrupts the balance between power generation and demand load due to the increased frequency fluctuation, which challenges the frequency stability analysis and control synthesis of power generation systems. This paper proposes a robust distributed load frequency control (DLFC) scheme for multi-area power systems. Firstly, a multi-area power system is constructed by integrating photovoltaic (PV) and battery energy storage systems (BESSs). Then, by employing the linear matrix inequality (LMI) technique, the sufficient condition capable of ensuring that the proposed controller satisfies H∞ robust performance in the sense of asymptotic stability is derived. Finally, testing is conducted on a four-area renewable power system, and results verify the strong robustness of the proposed controller against load disturbance and intermittence of RESs.

EnergiesVol. 17(22)
The Ohio State University (US)
Affordable and clean energy
Openalex Percentile: Top 17%
Frequency Control in Power Systems
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Robust Distributed Load Frequency Control for Multi-Area Power Systems with Photovoltaic and Battery Energy Storage System — Yunrui Lan, Mahesh S. Illindala · Energies (2024) | TGRS Research Map | TGRS