Determination of metal crack resistance on half-size Charpy specimens at cryogenic temperatures

The work consists in the manufacture of experimental equipment for fracture toughness tests at cryogenic temperatures in the range from -196 °Cto -80 °Cand the analysis of the efficiency of determining the reference temperature of a metal by the maker curve for static crack resistance in accordance with ASTM E 1921 and ASTM E399. Liquid nitrogen and its vapours were used to cool the samples to the required temperature. The temperature stability during sample loading was ensured within ±0.5°C around the required temperature. Pre-cracking of the samples was carried out at room temperature in accordance with ASTM E647. Experimental studies on static crack resistance are carried out for three-point bending using half-size Charpy specimens (55×10×5 mm) for the material - 10GN2MFA steel, which is used as the main metal for the main circulation pipelines of VVER-1000. The reference temperature is determined by processing a set of relevant experimental data.

Authors

Institutions

Publication Details

Journal
Mechanics and Advanced Technologies
Published
2024-09-30
DOI
https://doi.org/10.20535/2521-1943.2024.8.3(102).306592
Citations
1
Primary Topic
Fatigue and fracture mechanics
Type
article
Field-Weighted Citation Impact
0.27
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of metal crack resistance on half-size Charpy specimens at cryogenic temperatures

Maksym Zarazovskii, Volodymyr Iasnii, K. Lukianenko, Sergiy Shukayev
1 citations
Mechanics and Advanced Technologies
Fatigue and fracture mechanics
0.27
article

Determination of metal crack resistance on half-size Charpy specimens at cryogenic temperatures

Maksym Zarazovskii, Volodymyr Iasnii, K. Lukianenko, Sergiy Shukayev
article en
1 citations

Abstract

The work consists in the manufacture of experimental equipment for fracture toughness tests at cryogenic temperatures in the range from -196 °Cto -80 °Cand the analysis of the efficiency of determining the reference temperature of a metal by the maker curve for static crack resistance in accordance with ASTM E 1921 and ASTM E399. Liquid nitrogen and its vapours were used to cool the samples to the required temperature. The temperature stability during sample loading was ensured within ±0.5°C around the required temperature. Pre-cracking of the samples was carried out at room temperature in accordance with ASTM E647. Experimental studies on static crack resistance are carried out for three-point bending using half-size Charpy specimens (55×10×5 mm) for the material - 10GN2MFA steel, which is used as the main metal for the main circulation pipelines of VVER-1000. The reference temperature is determined by processing a set of relevant experimental data.

Mechanics and Advanced TechnologiesVol. 8(3(102))
National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute” (UA), Institut für Psychologische Psychotherapie (DE), Ternopil Ivan Pului National Technical University (UA)
Openalex Percentile: Top 48%
Fatigue and fracture mechanics
0.27
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Determination of metal crack resistance on half-size Charpy specimens at cryogenic temperatures — Maksym Zarazovskii, Volodymyr Iasnii, et al. · Mechanics and Advanced Technologies (2024) | TGRS Research Map | TGRS