Automated acute skin toxicity scoring in a mouse model through deep learning

This study presents a novel approach to skin toxicity assessment in preclinical radiotherapy trials through an advanced imaging setup and deep learning. Skin reactions, commonly associated with undesirable side effects in radiotherapy, were meticulously evaluated in 160 mice across four studies. A comprehensive dataset containing 7542 images was derived from proton/electron trials with matched manual scoring of the acute toxicity on the right hind leg, which was the target area irradiated in the trials. This dataset was the foundation for the subsequent model training. The two-step deep learning framework incorporated an object detection model for hind leg detection and a classification model for toxicity classification. An observer study involving five experts and the deep learning model, was conducted to analyze the retrospective capabilities and inter-observer variations. The results revealed that the hind leg object detection model exhibited a robust performance, achieving an accuracy of almost 99%. Subsequently, the classification model demonstrated an overall accuracy of about 85%, revealing nuanced challenges in specific toxicity grades. The observer study highlighted high inter-observer agreement and showcased the model's superiority in accuracy and misclassification distance. In conclusion, this study signifies an advancement in objective and reproducible skin toxicity assessment. The imaging and deep learning system not only allows for retrospective toxicity scoring, but also presents a potential for minimizing inter-observer variation and evaluation times, addressing critical gaps in manual scoring methodologies. Future recommendations include refining the system through an expanded training dataset, paving the way for its deployment in preclinical research and radiotherapy trials.

Authors

Institutions

Publication Details

Journal
Radiation and Environmental Biophysics
Published
2024-11-06
DOI
https://doi.org/10.1007/s00411-024-01096-x
Citations
2
Primary Topic
Image Processing Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.64

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated acute skin toxicity scoring in a mouse model through deep learning

Jasper Nijkamp, Line Kristensen, Brita Singers Sørensen, Priyanshu Sinha et al.
2 citations
Radiation and Environmental Biophysics
Image Processing Techniques and Applications
0.64
article

Automated acute skin toxicity scoring in a mouse model through deep learning

Jasper Nijkamp, Line Kristensen, Brita Singers Sørensen, Priyanshu Sinha, P.R. Poulsen, Folefac Charlemagne Asonganyi, Morten Sahlertz
article en
2 citations

Abstract

This study presents a novel approach to skin toxicity assessment in preclinical radiotherapy trials through an advanced imaging setup and deep learning. Skin reactions, commonly associated with undesirable side effects in radiotherapy, were meticulously evaluated in 160 mice across four studies. A comprehensive dataset containing 7542 images was derived from proton/electron trials with matched manual scoring of the acute toxicity on the right hind leg, which was the target area irradiated in the trials. This dataset was the foundation for the subsequent model training. The two-step deep learning framework incorporated an object detection model for hind leg detection and a classification model for toxicity classification. An observer study involving five experts and the deep learning model, was conducted to analyze the retrospective capabilities and inter-observer variations. The results revealed that the hind leg object detection model exhibited a robust performance, achieving an accuracy of almost 99%. Subsequently, the classification model demonstrated an overall accuracy of about 85%, revealing nuanced challenges in specific toxicity grades. The observer study highlighted high inter-observer agreement and showcased the model's superiority in accuracy and misclassification distance. In conclusion, this study signifies an advancement in objective and reproducible skin toxicity assessment. The imaging and deep learning system not only allows for retrospective toxicity scoring, but also presents a potential for minimizing inter-observer variation and evaluation times, addressing critical gaps in manual scoring methodologies. Future recommendations include refining the system through an expanded training dataset, paving the way for its deployment in preclinical research and radiotherapy trials.

Radiation and Environmental BiophysicsVol. 64(1)
Aarhus University (DK), Aarhus University Hospital (DK), Danish Pain Research Center (DK)
Aarhus Universitet, Kræftens Bekæmpelse, Novo Nordisk, Novo Nordisk Fonden
Good health and well-being
Openalex Percentile: Top 26%
Image Processing Techniques and Applications
0.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.