Automatic delineation of cervical cancer target volumes in small samples based on multi-decoder and semi-supervised learning and clinical application

Radiotherapy has been demonstrated to be one of the most significant treatments for cervical cancer, during which accurate and efficient delineation of target volumes is critical. To alleviate the data demand of deep learning and promote the establishment and promotion of auto-segmentation models in small and medium-sized oncology departments and single centres, we proposed an auto-segmentation algorithm to determine the cervical cancer target volume in small samples based on multi-decoder and semi-supervised learning (MDSSL), and we evaluated the accuracy via an independent test cohort. In this study, we retrospectively collected computed tomography (CT) datasets from 71 pelvic cervical cancer patients, and a 3:4 ratio was used for the training and testing sets. The clinical target volumes (CTVs) of the primary tumour area (CTV1) and pelvic lymph drainage area (CTV2) were delineated. For definitive radiotherapy (dRT), the primary gross target volume (GTVp) was simultaneously delineated. According to the data characteristics for small samples, the MDSSL network structure based on 3D U-Net was established to train the model by combining clinical anatomical information, which was compared with other segmentation methods, including supervised learning (SL) and transfer learning (TL). The dice similarity coefficient (DSC), 95% Hausdorff distance (HD95) and average surface distance (ASD) were used to evaluate the segmentation performance. The ability of the segmentation algorithm to improve the efficiency of online adaptive radiation therapy (ART) was assessed via geometric indicators and a subjective evaluation of radiation oncologists (ROs) in prospective clinical applications. Compared with the SL model and TL model, the proposed MDSSL model displayed the best DSC, HD95 and ASD overall, especially for the GTVp of dRT. We calculated the above geometric indicators in the range of the ground truth (head-foot direction). In the test set, the DSC, HD95 and ASD of the MDSSL model were 0.80/5.85 mm/0.95 mm for CTV1 of post-operative radiotherapy (pRT), 0.84/ 4.88 mm/0.73 mm for CTV2 of pRT, 0.84/6.58 mm/0.89 mm for GTVp of dRT, 0.85/5.36 mm/1.35 mm for CTV1 of dRT, and 0.84/4.09 mm/0.73 mm for CTV2 of dRT, respectively. In a prospective clinical study of online ART, the target volume modification time (MTime) was 3-5 min for dRT and 2-4 min for pRT, and the main duration of CTV1 modification was approximately 2 min. The introduction of the MDSSL method successfully improved the accuracy of auto-segmentation for the cervical cancer target volume in small samples, showed good consistency with RO delineation and satisfied clinical requirements. In this prospective online ART study, the application of the segmentation model was demonstrated to be useful for reducing the target volume delineation time and improving the efficiency of the online ART workflow, which can contribute to the development and promotion of cervical cancer online ART.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-11-06
DOI
https://doi.org/10.1038/s41598-024-78424-0
Citations
3
Primary Topic
AI in cancer detection
Type
article
Field-Weighted Citation Impact
1.04

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automatic delineation of cervical cancer target volumes in small samples based on multi-decoder and semi-supervised learning and clinical application

Fang Yang, Lecheng Jia, Dong Gao, Ningyue Xu et al.
3 citations
Scientific Reports
AI in cancer detection
1.04
article

Automatic delineation of cervical cancer target volumes in small samples based on multi-decoder and semi-supervised learning and clinical application

Fang Yang, Lecheng Jia, Dong Gao, Ningyue Xu, Fengyu Lin, Haibo Peng, P. L. Li, Xing Luo, Tao Ren, Xiaoqing Sun, X. L. Wang, Huigang Tan, Tao Liu
article en
3 citations

Abstract

Radiotherapy has been demonstrated to be one of the most significant treatments for cervical cancer, during which accurate and efficient delineation of target volumes is critical. To alleviate the data demand of deep learning and promote the establishment and promotion of auto-segmentation models in small and medium-sized oncology departments and single centres, we proposed an auto-segmentation algorithm to determine the cervical cancer target volume in small samples based on multi-decoder and semi-supervised learning (MDSSL), and we evaluated the accuracy via an independent test cohort. In this study, we retrospectively collected computed tomography (CT) datasets from 71 pelvic cervical cancer patients, and a 3:4 ratio was used for the training and testing sets. The clinical target volumes (CTVs) of the primary tumour area (CTV1) and pelvic lymph drainage area (CTV2) were delineated. For definitive radiotherapy (dRT), the primary gross target volume (GTVp) was simultaneously delineated. According to the data characteristics for small samples, the MDSSL network structure based on 3D U-Net was established to train the model by combining clinical anatomical information, which was compared with other segmentation methods, including supervised learning (SL) and transfer learning (TL). The dice similarity coefficient (DSC), 95% Hausdorff distance (HD95) and average surface distance (ASD) were used to evaluate the segmentation performance. The ability of the segmentation algorithm to improve the efficiency of online adaptive radiation therapy (ART) was assessed via geometric indicators and a subjective evaluation of radiation oncologists (ROs) in prospective clinical applications. Compared with the SL model and TL model, the proposed MDSSL model displayed the best DSC, HD95 and ASD overall, especially for the GTVp of dRT. We calculated the above geometric indicators in the range of the ground truth (head-foot direction). In the test set, the DSC, HD95 and ASD of the MDSSL model were 0.80/5.85 mm/0.95 mm for CTV1 of post-operative radiotherapy (pRT), 0.84/ 4.88 mm/0.73 mm for CTV2 of pRT, 0.84/6.58 mm/0.89 mm for GTVp of dRT, 0.85/5.36 mm/1.35 mm for CTV1 of dRT, and 0.84/4.09 mm/0.73 mm for CTV2 of dRT, respectively. In a prospective clinical study of online ART, the target volume modification time (MTime) was 3-5 min for dRT and 2-4 min for pRT, and the main duration of CTV1 modification was approximately 2 min. The introduction of the MDSSL method successfully improved the accuracy of auto-segmentation for the cervical cancer target volume in small samples, showed good consistency with RO delineation and satisfied clinical requirements. In this prospective online ART study, the application of the segmentation model was demonstrated to be useful for reducing the target volume delineation time and improving the efficiency of the online ART workflow, which can contribute to the development and promotion of cervical cancer online ART.

Scientific ReportsVol. 14(1)
Chengdu Medical College (CN), West China Medical Center of Sichuan University (CN), Chengdu Military General Hospital (CN), First Affiliated Hospital of Chengdu Medical College (CN), United Imaging Healthcare (China) (CN), Science and Technology Department of Sichuan Province (CN), Chengdu University of Traditional Chinese Medicine (CN)
Health Commission of Sichuan Province, Sichuan Province Science and Technology Support Program
Openalex Percentile: Top 18%
AI in cancer detection
1.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.