Comparative numerical study of the energy performance of two different configurations of a hybrid photovoltaic/thermal air collector

Solar energy is a renewable alternative to fossil fuels. When solar energy is converted into electricity by photovoltaic (PV) solar modules, the heat generated increases the temperature of the PV solar cells and, as a result, reduces their electrical efficiency. Several techniques are used to cool PV solar cells in order to reduce their operating temperature. One technique is the use of hybrid photovoltaic/thermal (PVT) solar collectors, which simultaneously produce electricity and useful heat. In the airflow channel, the heat and mass transfer equations and those derived from the energy balance on the solid layers of the collector were discretized using the finite difference method with an implicit alternating directions (ADI) scheme. All the algebraic equations obtained after discretization were solved using the Thomas algorithm. The aim is to make a numerical comparison of the energy performance of the Verre-PV-Tedlar and Verre-PV-Verre flat-plate air PVT hybrid solar collectors in the climatic conditions of Lomé, Togo. Under the same operating conditions, the average electrical efficiencies of the Verre-PV-Verre and Verre-PV-Tedlar flat-plate air PVT hybrid collectors are 15.34% and 13.85% respectively. There is a 1.49% improvement in electrical efficiency for a Verre-PV-Verre air-source PVT hybrid collector compared with a Verre-PV-Tedlar PVT hybrid collector. The Verre-PV-Verre flat plate PVT air hybrid collector has an average daily electrical energy gain of 0.564 kWh and a thermal energy gain of 0.839 kWh, while the Verre-PV-Tedlar flat plate PVT air hybrid collector has an average daily electrical energy gain of 0.548 kWh and a thermal energy gain of 1.403 kWh.

Authors

Institutions

Publication Details

Journal
Edelweiss Applied Science and Technology
Published
2024-11-05
DOI
https://doi.org/10.55214/25768484.v8i6.2846
Citations
1
Primary Topic
Solar Thermal and Photovoltaic Systems
Type
article
Field-Weighted Citation Impact
0.10
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative numerical study of the energy performance of two different configurations of a hybrid photovoltaic/thermal air collector

Yendouban Kolani, Kokou N’wuitcha, Komlan Déla Donald Aoukou, Yao Kombate et al.
1 citations
Edelweiss Applied Science and Technology
Solar Thermal and Photovoltaic Systems
0.10
article

Comparative numerical study of the energy performance of two different configurations of a hybrid photovoltaic/thermal air collector

Yendouban Kolani, Kokou N’wuitcha, Komlan Déla Donald Aoukou, Yao Kombate, Koffi Gagnon Apedanou, Bernard Obese, N’Gissa Attah
article en
1 citations

Abstract

Solar energy is a renewable alternative to fossil fuels. When solar energy is converted into electricity by photovoltaic (PV) solar modules, the heat generated increases the temperature of the PV solar cells and, as a result, reduces their electrical efficiency. Several techniques are used to cool PV solar cells in order to reduce their operating temperature. One technique is the use of hybrid photovoltaic/thermal (PVT) solar collectors, which simultaneously produce electricity and useful heat. In the airflow channel, the heat and mass transfer equations and those derived from the energy balance on the solid layers of the collector were discretized using the finite difference method with an implicit alternating directions (ADI) scheme. All the algebraic equations obtained after discretization were solved using the Thomas algorithm. The aim is to make a numerical comparison of the energy performance of the Verre-PV-Tedlar and Verre-PV-Verre flat-plate air PVT hybrid solar collectors in the climatic conditions of Lomé, Togo. Under the same operating conditions, the average electrical efficiencies of the Verre-PV-Verre and Verre-PV-Tedlar flat-plate air PVT hybrid collectors are 15.34% and 13.85% respectively. There is a 1.49% improvement in electrical efficiency for a Verre-PV-Verre air-source PVT hybrid collector compared with a Verre-PV-Tedlar PVT hybrid collector. The Verre-PV-Verre flat plate PVT air hybrid collector has an average daily electrical energy gain of 0.564 kWh and a thermal energy gain of 0.839 kWh, while the Verre-PV-Tedlar flat plate PVT air hybrid collector has an average daily electrical energy gain of 0.548 kWh and a thermal energy gain of 1.403 kWh.

Edelweiss Applied Science and TechnologyVol. 8(6)
University of Cape Coast (GH), University of Lomé (TG)
Affordable and clean energy
Openalex Percentile: Top 64%
Solar Thermal and Photovoltaic Systems
0.10
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.