Polytetrafluoroethylene Felt Inlay Neomedia and Tissue Glue Do Not Prevent Reoperation in Type A Aortic Dissection

<b>Background/Objectives:</b> Type A aortic dissection repair using Polytetrafluorethylene (PTFE) felt inlay and tissue glue has been proposed as a treatment modality. It remains unclear, if this method performs superiorly to tissue glue only. <b>Methods:</b> Between January 2011 and December 2015, 139 patients underwent surgical repair for type A aortic dissection, and 48 patients were excluded (<i>n</i> = 29 after receiving a composite graft, <i>n</i> = 18 in which no tissue glue was used, and <i>n</i> = 1 due to missing data). In the remaining patients, proximal aortic repair was performed either using PTFE felt inlay and tissue glue or tissue glue only. We analyzed the need for repeated surgery on the aorta during follow-up as a primary endpoint. The secondary endpoint was all-cause mortality at follow-up. Inverse probability of treatment weighting was used to balance the distribution of measured baseline covariates. <b>Results:</b> Sixty-six patients (73%) were treated with a tissue-glue-only approach-the Control Group. Twenty-five patients (27%) underwent proximal PTFE felt inlay and tissue glue-the Intervention Group. In the Intervention Group, 40% (<i>n</i> = 10) underwent reoperation due to re-dissection or pseudoaneurysm vs. 12% (<i>n</i> = 8) in the Control Group. The felt inlay increased the hazard of re-operation by 8.38 (1.63 to 43.0) after IPTW with death modeled as competing risk. <b>Conclusions:</b> Reoperation due to aortic complications was 10 times higher in patients treated with a combination of gluing and PTFE felt inlay vs. gluing only. These results are potentially caused by an interaction of PTFE, tissue glue, and aortic tissue.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2024-11-06
DOI
https://doi.org/10.3390/jcm13226663
Citations
1
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
0.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Polytetrafluoroethylene Felt Inlay Neomedia and Tissue Glue Do Not Prevent Reoperation in Type A Aortic Dissection

Jules Miazza, Brigitta Gahl, Oliver Reuthebuch, Luca Koechlin et al.
1 citations
Journal of Clinical Medicine
Aortic Disease and Treatment Approaches
0.42
article

Polytetrafluoroethylene Felt Inlay Neomedia and Tissue Glue Do Not Prevent Reoperation in Type A Aortic Dissection

Jules Miazza, Brigitta Gahl, Oliver Reuthebuch, Luca Koechlin, Denis Berdajs, Luise Vöhringer, Friedrich Eckstein
article en
1 citations

Abstract

<b>Background/Objectives:</b> Type A aortic dissection repair using Polytetrafluorethylene (PTFE) felt inlay and tissue glue has been proposed as a treatment modality. It remains unclear, if this method performs superiorly to tissue glue only. <b>Methods:</b> Between January 2011 and December 2015, 139 patients underwent surgical repair for type A aortic dissection, and 48 patients were excluded (<i>n</i> = 29 after receiving a composite graft, <i>n</i> = 18 in which no tissue glue was used, and <i>n</i> = 1 due to missing data). In the remaining patients, proximal aortic repair was performed either using PTFE felt inlay and tissue glue or tissue glue only. We analyzed the need for repeated surgery on the aorta during follow-up as a primary endpoint. The secondary endpoint was all-cause mortality at follow-up. Inverse probability of treatment weighting was used to balance the distribution of measured baseline covariates. <b>Results:</b> Sixty-six patients (73%) were treated with a tissue-glue-only approach-the Control Group. Twenty-five patients (27%) underwent proximal PTFE felt inlay and tissue glue-the Intervention Group. In the Intervention Group, 40% (<i>n</i> = 10) underwent reoperation due to re-dissection or pseudoaneurysm vs. 12% (<i>n</i> = 8) in the Control Group. The felt inlay increased the hazard of re-operation by 8.38 (1.63 to 43.0) after IPTW with death modeled as competing risk. <b>Conclusions:</b> Reoperation due to aortic complications was 10 times higher in patients treated with a combination of gluing and PTFE felt inlay vs. gluing only. These results are potentially caused by an interaction of PTFE, tissue glue, and aortic tissue.

Journal of Clinical MedicineVol. 13(22)
University of Basel (CH), University Hospital of Basel (CH)
Openalex Percentile: Top 31%
Aortic Disease and Treatment Approaches
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.