Temperature Distribution of Frozen Wall Formed by Irregular Hole Arrangement During In Situ Repair of Underground Shield Machine

In order to study the development law of the irregular hole freezing temperature field, combined with the shield solution project of the Nanjing Water Supply Corridor, the distribution characteristics and influencing factors of the irregular freezing temperature field of the river bottom shield machine are studied by numerical simulation. The following conclusions are obtained: (1) The extension length of the outer ring pipe is correlated approximately positively with the thickness and average temperature of the freezing wall at the bottom of the cup. The thickness increases by 0.25 m, and the average temperature decreases by 1.25 °C for every 1 m increase in the extension length. (2) The intersection time decreases logarithmically with the increase in the extension length of the outer ring tube. (3) As the ratio of the axial angle between the two adjacent tubes in the weak area of the outer ring tube becomes larger, the temperature of the weak point in the center of the two tubes increases approximately linearly. The midpoint temperature of the two tubes increases by 3.3 °C for every 1 increase in the angle coefficient. (4) With the increase in the opening angle of the inner ring hole, the thickness and average temperature change, respectively, at 150 d are not more than 0.15 m and 0.6 °C. The results show that under the irregular freezing form, the angle and length of the outer ring pipe have a great influence on the temperature field, and the angle of the inner ring pipe has little influence on the final distribution of the temperature field. The average temperature and the temperature distribution of the weak points show a trend of decreasing first and then increasing along the shield advancing direction, reaching a minimum near the cutterhead.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2024-11-06
DOI
https://doi.org/10.3390/app142210167
Primary Topic
Tunneling and Rock Mechanics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Temperature Distribution of Frozen Wall Formed by Irregular Hole Arrangement During In Situ Repair of Underground Shield Machine

C. N. H. Long, Zequn Hong, Shi Rong-jian, Yajing Qian
Applied Sciences
Tunneling and Rock Mechanics
article

Temperature Distribution of Frozen Wall Formed by Irregular Hole Arrangement During In Situ Repair of Underground Shield Machine

C. N. H. Long, Zequn Hong, Shi Rong-jian, Yajing Qian
article en

Abstract

In order to study the development law of the irregular hole freezing temperature field, combined with the shield solution project of the Nanjing Water Supply Corridor, the distribution characteristics and influencing factors of the irregular freezing temperature field of the river bottom shield machine are studied by numerical simulation. The following conclusions are obtained: (1) The extension length of the outer ring pipe is correlated approximately positively with the thickness and average temperature of the freezing wall at the bottom of the cup. The thickness increases by 0.25 m, and the average temperature decreases by 1.25 °C for every 1 m increase in the extension length. (2) The intersection time decreases logarithmically with the increase in the extension length of the outer ring tube. (3) As the ratio of the axial angle between the two adjacent tubes in the weak area of the outer ring tube becomes larger, the temperature of the weak point in the center of the two tubes increases approximately linearly. The midpoint temperature of the two tubes increases by 3.3 °C for every 1 increase in the angle coefficient. (4) With the increase in the opening angle of the inner ring hole, the thickness and average temperature change, respectively, at 150 d are not more than 0.15 m and 0.6 °C. The results show that under the irregular freezing form, the angle and length of the outer ring pipe have a great influence on the temperature field, and the angle of the inner ring pipe has little influence on the final distribution of the temperature field. The average temperature and the temperature distribution of the weak points show a trend of decreasing first and then increasing along the shield advancing direction, reaching a minimum near the cutterhead.

Applied SciencesVol. 14(22)
China University of Mining and Technology (CN)
National Natural Science Foundation of China
Clean water and sanitation
Openalex Percentile: Top 77%
Tunneling and Rock Mechanics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Temperature Distribution of Frozen Wall Formed by Irregular Hole Arrangement During In Situ Repair of Underground Shield Machine — C. N. H. Long, Zequn Hong, et al. · Applied Sciences (2024) | TGRS Research Map | TGRS