Study of High-Frequency Pulsating Flow Control Valves

Pulsating flow signals are widely used in the fields of dynamic calibration of flow meters and reliability testing of fluid transmission pipelines. A high-frequency pulsating flow control valve is proposed, its structure and working principle are introduced, and its mathematical model is also established. Finally, an experimental platform is built to experimentally verify the performance of the high-frequency pulsating flow signal generation of this flow control valve prototype. When applying sinusoidal flow signals of 1–25 Hz, the amplitude of the output flow starts to decay after 2 Hz, and the frequency corresponding to the decay to −3 dB is about 23.5 Hz. The experimental results show that the valve can effectively generate unidirectional sinusoidal flow with a maximum amplitude of 25 L/min and a frequency of 23.5 Hz.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2024-11-06
DOI
https://doi.org/10.3390/app142210177
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of High-Frequency Pulsating Flow Control Valves

Chuan Ding, Yulin Wu, Ke Zhu, Jian Ruan et al.
Applied Sciences
Refrigeration and Air Conditioning Technologies
article

Study of High-Frequency Pulsating Flow Control Valves

Chuan Ding, Yulin Wu, Ke Zhu, Jian Ruan, R. S. Shi, Dongdong Zhang
article en

Abstract

Pulsating flow signals are widely used in the fields of dynamic calibration of flow meters and reliability testing of fluid transmission pipelines. A high-frequency pulsating flow control valve is proposed, its structure and working principle are introduced, and its mathematical model is also established. Finally, an experimental platform is built to experimentally verify the performance of the high-frequency pulsating flow signal generation of this flow control valve prototype. When applying sinusoidal flow signals of 1–25 Hz, the amplitude of the output flow starts to decay after 2 Hz, and the frequency corresponding to the decay to −3 dB is about 23.5 Hz. The experimental results show that the valve can effectively generate unidirectional sinusoidal flow with a maximum amplitude of 25 L/min and a frequency of 23.5 Hz.

Applied SciencesVol. 14(22)
Zhejiang University of Technology (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 80%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Study of High-Frequency Pulsating Flow Control Valves — Chuan Ding, Yulin Wu, et al. · Applied Sciences (2024) | TGRS Research Map | TGRS