The Characterization of Aquifer Parameters in Using Skimming Tubewells Through the Pumping Test Method: A Case Study of Tando Allahyar

Sindh is in the lower reaches of the Indus River; it is most vulnerable to a variety of upstream water development challenges. The aim of this research was to determine aquifer characteristics in the command area of Tando Allahyar-II distributary within the culmination of underground water potential. The hydraulic properties of the aquifer as well as the susceptibility of the formation to tedious extraction and saltwater upcoming were recognized. Three pumping tests were performed at head, middle, and tail reaches along the selected distributary. The drawdowns were measured at head reach (5.1667 h), at middle reach (6.0 h), and at tail reach (19.667 h) of the selected distributary by performing the pumping tests. Groundwater levels were lower at the tail reach compared to those at the head and middle reaches, likely due to a higher concentration of tubewells in the lower reach. The head and middle reaches showed higher groundwater levels, possibly due to constant head conditions promoting infiltration and recharge. The pumping test versus drawdown analysis revealed that the tubewells should be run with 7-h (on) and 4-h (off) operation. Further, the tubewells at all reaches (head, middle, and tail) should be closed for a minimum of 4 h between operations. This strategy would allow safe groundwater extraction, maintain water quality, and prevent water table depletion in the study area. The hydrodynamic and hydro-salinity behaviors were scrutinized in PWMIN 5.3 (version) by means of the MODFLOW mode. The results were estimated to compare the calibration and validation simulation outcomes using measured data. The model was successfully calibrated, and the root mean square (RMS) value of the head tubewell varied between 0.024 and 0.108, whereas it speckled between 0.0166 and 0.0349 for the middle tubewell and between 0.0659 and 0.0069 for the tail tubewell. The RMS values for hydrodynamic behavior for the head, middle, and tail reaches were less than 10%. These values represent a suitable match between the observed and simulated heads when a water table depletion of 1 to 2 m was observed due to extreme pumping. However, the average relative error values, for all validated procedures, were less than 10%.

Authors

Institutions

Publication Details

Journal
Water
Published
2024-11-06
DOI
https://doi.org/10.3390/w16223180
Primary Topic
Groundwater flow and contamination studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Characterization of Aquifer Parameters in Using Skimming Tubewells Through the Pumping Test Method: A Case Study of Tando Allahyar

S. M. Kori, Xiufang Yang, Muhammad Uris Mirjat, Farman Ali Chandio et al.
Water
Groundwater flow and contamination studies
article

The Characterization of Aquifer Parameters in Using Skimming Tubewells Through the Pumping Test Method: A Case Study of Tando Allahyar

S. M. Kori, Xiufang Yang, Muhammad Uris Mirjat, Farman Ali Chandio, Rajesh Kumar Soothar, Sher Ali Shaikh, Irshad Ali Mari, Mashooque Ali Talpur, Abdullah Baloch
article en

Abstract

Sindh is in the lower reaches of the Indus River; it is most vulnerable to a variety of upstream water development challenges. The aim of this research was to determine aquifer characteristics in the command area of Tando Allahyar-II distributary within the culmination of underground water potential. The hydraulic properties of the aquifer as well as the susceptibility of the formation to tedious extraction and saltwater upcoming were recognized. Three pumping tests were performed at head, middle, and tail reaches along the selected distributary. The drawdowns were measured at head reach (5.1667 h), at middle reach (6.0 h), and at tail reach (19.667 h) of the selected distributary by performing the pumping tests. Groundwater levels were lower at the tail reach compared to those at the head and middle reaches, likely due to a higher concentration of tubewells in the lower reach. The head and middle reaches showed higher groundwater levels, possibly due to constant head conditions promoting infiltration and recharge. The pumping test versus drawdown analysis revealed that the tubewells should be run with 7-h (on) and 4-h (off) operation. Further, the tubewells at all reaches (head, middle, and tail) should be closed for a minimum of 4 h between operations. This strategy would allow safe groundwater extraction, maintain water quality, and prevent water table depletion in the study area. The hydrodynamic and hydro-salinity behaviors were scrutinized in PWMIN 5.3 (version) by means of the MODFLOW mode. The results were estimated to compare the calibration and validation simulation outcomes using measured data. The model was successfully calibrated, and the root mean square (RMS) value of the head tubewell varied between 0.024 and 0.108, whereas it speckled between 0.0166 and 0.0349 for the middle tubewell and between 0.0659 and 0.0069 for the tail tubewell. The RMS values for hydrodynamic behavior for the head, middle, and tail reaches were less than 10%. These values represent a suitable match between the observed and simulated heads when a water table depletion of 1 to 2 m was observed due to extreme pumping. However, the average relative error values, for all validated procedures, were less than 10%.

WaterVol. 16(22)
Mehran University of Engineering and Technology (PK), Yangzhou Polytechnic Institute (CN), Sindh Agriculture University (PK)
Government of Jiangsu Province
Clean water and sanitation
Openalex Percentile: Top 82%
Groundwater flow and contamination studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.