Fault-tolerant cascaded H-bridge inverter connected to power grid

Nowadays, the use of inverters is increasingly required in domestic and industrial installations, electrical energy production plants, and in several other areas for the conversion from the DC form to the AC form of the electrical energy such as aviation, maritime and especially in the field of Parallel Active Filtering where it constitutes the capital element for the injection of harmonic compensating energy into the electrical network. In the interest of ensuring its reliability and especially its availability, it is therefore important to design its fault-tolerant model. In this paper, we propose a new model of cascaded H-bridge inverter which could even in the presence of faults, continue to deliver a voltage of value equal to that in normal operating mode. The results of simulations carried out using the Matlab/Simulink software show good performance of the proposed inverter.

Authors

Publication Details

Journal
Global Journal of Engineering and Technology Advances
Published
2024-11-06
DOI
https://doi.org/10.30574/gjeta.2024.21.2.0183
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fault-tolerant cascaded H-bridge inverter connected to power grid

Golam Guidkaya, Dalenda Ben Issa, Philippe Djondiné, Emmanuel DOBSOUMNA et al.
Global Journal of Engineering and Technology Advances
Multilevel Inverters and Converters
article

Fault-tolerant cascaded H-bridge inverter connected to power grid

Golam Guidkaya, Dalenda Ben Issa, Philippe Djondiné, Emmanuel DOBSOUMNA, Frédéric RONWE DJORWE, Ali ADAMA HADJA
article en

Abstract

Nowadays, the use of inverters is increasingly required in domestic and industrial installations, electrical energy production plants, and in several other areas for the conversion from the DC form to the AC form of the electrical energy such as aviation, maritime and especially in the field of Parallel Active Filtering where it constitutes the capital element for the injection of harmonic compensating energy into the electrical network. In the interest of ensuring its reliability and especially its availability, it is therefore important to design its fault-tolerant model. In this paper, we propose a new model of cascaded H-bridge inverter which could even in the presence of faults, continue to deliver a voltage of value equal to that in normal operating mode. The results of simulations carried out using the Matlab/Simulink software show good performance of the proposed inverter.

Global Journal of Engineering and Technology AdvancesVol. 21(2)
Affordable and clean energy
Openalex Percentile: Top 83%
Multilevel Inverters and Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fault-tolerant cascaded H-bridge inverter connected to power grid — Golam Guidkaya, Dalenda Ben Issa, et al. · Global Journal of Engineering and Technology Advances (2024) | TGRS Research Map | TGRS