Breathing pattern and ventilatory response to exercise in chronic obstructive pulmonary disease

<bold>Background and Aim:</bold> Patients with chronic obstructive pulmonary disease (COPD) show a ventilatory limitation to exercise due to ventilatory inefficiency and dynamic hyperinflation (DH). Breathing pattern can be measured by T<sub>I</sub>/T<sub>TOT</sub> (inspiratory time/total time) and V<sub>T</sub>/T<sub>I</sub> (tidal volume/inspiratory time), that increase during exertional hyperpnea in healthy subjects. These parameters have never been studied in COPD, so we analysed them at rest and on exercise in a COPD cohort. <bold>Methods:</bold> We retrospectively enrolled stable COPD patients with a variable airflow obstruction. They all underwent spirometry and cardiopulmonary exercise testing on a cycle ergometer. <bold>Results:</bold> In 234 COPD patients (75 females; age range 41-89 years; BMI 27±5 kg/m<sup>2</sup>), T<sub>I</sub>/T<sub>TOT</sub> and V<sub>T</sub>/T<sub>I</sub> increased from 0.259±0.040 to 0.304±0.038 and from 854.1±229,6 ml/s to 2100±622.5 ml/s, respectively (p<0.05) during exercise. T<sub>I</sub>/T<sub>TOT</sub> and V<sub>T</sub>/T<sub>I</sub> at peak were both positively related (p<0.05) with VO<sub>2peak</sub> (ml/min/kg) and maximal workload (Watt). T<sub>I</sub>/T<sub>TOT</sub> at rest and at peak showed a positive correlation (p<0.05) with the peak-rest difference in inspiratory capacity (ΔIC, in ml). Clustering patients according to the development of DH (ΔIC ≥150 ml), a T<sub>I</sub>/T<sub>TOT</sub> at peak ≤ 0.302 (AUC = 0.697, p<0.001; sensitivity: 0.705 specificity: 0.605) and a T<sub>I</sub>/T<sub>TOT</sub> at rest ≤ 0.266 (AUC = 0.620, p<0.05, sensitivity 0.585 specificity 0.612) significantly predicted the development of DH. <bold>Conclusions:</bold> T<sub>I</sub>/T<sub>TOT</sub> and V<sub>T</sub>/T<sub>I</sub> significantly increase during maximal exercise in COPD. T<sub>I</sub>/T<sub>TOT</sub> at both rest and peak significantly correlated with DH and also predicted its development. T<sub>I</sub>/T<sub>TOT</sub> and V<sub>T</sub>/T<sub>I</sub> may be useful measures of the ventilatory response to exercise in COPD.

Authors

Institutions

Publication Details

Published
2024-09-14
DOI
https://doi.org/10.1183/13993003.congress-2024.oa1956
Primary Topic
Chronic Obstructive Pulmonary Disease (COPD) Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Breathing pattern and ventilatory response to exercise in chronic obstructive pulmonary disease

Annalisa Frizzelli, Luigino Calzetta, Rocco Accogli, O. B. Bondarenko et al.
Chronic Obstructive Pulmonary Disease (COPD) Research
article

Breathing pattern and ventilatory response to exercise in chronic obstructive pulmonary disease

Annalisa Frizzelli, Luigino Calzetta, Rocco Accogli, O. B. Bondarenko, Panagiota Tzani, Roberta Pisi, Alfredo Chetta, Marina Aiello
article en

Abstract

<bold>Background and Aim:</bold> Patients with chronic obstructive pulmonary disease (COPD) show a ventilatory limitation to exercise due to ventilatory inefficiency and dynamic hyperinflation (DH). Breathing pattern can be measured by T<sub>I</sub>/T<sub>TOT</sub> (inspiratory time/total time) and V<sub>T</sub>/T<sub>I</sub> (tidal volume/inspiratory time), that increase during exertional hyperpnea in healthy subjects. These parameters have never been studied in COPD, so we analysed them at rest and on exercise in a COPD cohort. <bold>Methods:</bold> We retrospectively enrolled stable COPD patients with a variable airflow obstruction. They all underwent spirometry and cardiopulmonary exercise testing on a cycle ergometer. <bold>Results:</bold> In 234 COPD patients (75 females; age range 41-89 years; BMI 27±5 kg/m<sup>2</sup>), T<sub>I</sub>/T<sub>TOT</sub> and V<sub>T</sub>/T<sub>I</sub> increased from 0.259±0.040 to 0.304±0.038 and from 854.1±229,6 ml/s to 2100±622.5 ml/s, respectively (p<0.05) during exercise. T<sub>I</sub>/T<sub>TOT</sub> and V<sub>T</sub>/T<sub>I</sub> at peak were both positively related (p<0.05) with VO<sub>2peak</sub> (ml/min/kg) and maximal workload (Watt). T<sub>I</sub>/T<sub>TOT</sub> at rest and at peak showed a positive correlation (p<0.05) with the peak-rest difference in inspiratory capacity (ΔIC, in ml). Clustering patients according to the development of DH (ΔIC ≥150 ml), a T<sub>I</sub>/T<sub>TOT</sub> at peak ≤ 0.302 (AUC = 0.697, p<0.001; sensitivity: 0.705 specificity: 0.605) and a T<sub>I</sub>/T<sub>TOT</sub> at rest ≤ 0.266 (AUC = 0.620, p<0.05, sensitivity 0.585 specificity 0.612) significantly predicted the development of DH. <bold>Conclusions:</bold> T<sub>I</sub>/T<sub>TOT</sub> and V<sub>T</sub>/T<sub>I</sub> significantly increase during maximal exercise in COPD. T<sub>I</sub>/T<sub>TOT</sub> at both rest and peak significantly correlated with DH and also predicted its development. T<sub>I</sub>/T<sub>TOT</sub> and V<sub>T</sub>/T<sub>I</sub> may be useful measures of the ventilatory response to exercise in COPD.

University of Parma (IT), Kharkiv National Medical University (UA)
Good health and well-being
Openalex Percentile: Top 63%
Chronic Obstructive Pulmonary Disease (COPD) Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.