Forceps and cryobiopsy of peripheral pulmonary lesions with 1.1 or 1.7 mm cryoprobes: An open-label, randomised trial

Lung cancer screening has increased the detection of peripheral pulmonary lesions (PPLs). Our study compares the safety and efficacy of transbronchial cryobiopsy with two probe diameters and forceps biopsy for the diagnosis of PPLs. This single-centre, investigator-initiated, randomised trial included patients with PPLs who required flexible bronchoscopy with radial endobronchial ultrasound-guided biopsy for histopathological diagnosis. Patients received a forceps biopsy and were randomly assigned to a cryobiopsy with a 1.1 mm (freezing time 7-10 sec) or a 1.7mm cryoprobe (freezing time 4-6 sec), respectively. The primary outcome was the diagnostic yield; further outcomes included total biopsy size, the proportion of malignant tissue, artefact-free alveolar space percentage, molecular pathology of the specimen and safety. Fifty-four patients (66.52±9.81 years; 48.1% male) with a median nodule size of 24mm [IQR 19 to 30] were included. The overall diagnostic yield was similar in the 1.1 mm and 1.7 mm groups (75.9% vs. 88.0%, p=0.261), and the specimens obtained with the two different cryoprobes were equal in size, quality, and information about molecular pathology. There was no difference in procedural-related bleeding between the groups (p=0.847). Compared to forceps biopsies, cryobiopsies had a superior overall diagnostic yield (75.9% vs. 48.1%, p=0.001) and were better suited for further molecular analysis (p=0.001). The 1.1 mm and 1.7 mm cryoprobes displayed comparable diagnostic yield, ability to provide molecular pathology information, and safety. Forceps biopsy was inferior to cryobiopsy in all aspects except safety.

Authors

Institutions

Publication Details

Journal
Lung Cancer
Published
2024-09-14
DOI
https://doi.org/10.1183/13993003.congress-2024.oa4680
Primary Topic
Medical Imaging and Pathology Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Forceps and cryobiopsy of peripheral pulmonary lesions with 1.1 or 1.7 mm cryoprobes: An open-label, randomised trial

Malcolm Kohler, Silvia Ulrich, Silvan Vesenbeckh, Maurice Roeder et al.
Lung Cancer
Medical Imaging and Pathology Studies
article

Forceps and cryobiopsy of peripheral pulmonary lesions with 1.1 or 1.7 mm cryoprobes: An open-label, randomised trial

Malcolm Kohler, Silvia Ulrich, Silvan Vesenbeckh, Maurice Roeder, Miriam Nowack, Carolin Steinack, Martina Haberecker, Thomas Gaisl, Jan H. Rüschoff, Daniel Franzen
article en

Abstract

Lung cancer screening has increased the detection of peripheral pulmonary lesions (PPLs). Our study compares the safety and efficacy of transbronchial cryobiopsy with two probe diameters and forceps biopsy for the diagnosis of PPLs. This single-centre, investigator-initiated, randomised trial included patients with PPLs who required flexible bronchoscopy with radial endobronchial ultrasound-guided biopsy for histopathological diagnosis. Patients received a forceps biopsy and were randomly assigned to a cryobiopsy with a 1.1 mm (freezing time 7-10 sec) or a 1.7mm cryoprobe (freezing time 4-6 sec), respectively. The primary outcome was the diagnostic yield; further outcomes included total biopsy size, the proportion of malignant tissue, artefact-free alveolar space percentage, molecular pathology of the specimen and safety. Fifty-four patients (66.52±9.81 years; 48.1% male) with a median nodule size of 24mm [IQR 19 to 30] were included. The overall diagnostic yield was similar in the 1.1 mm and 1.7 mm groups (75.9% vs. 88.0%, p=0.261), and the specimens obtained with the two different cryoprobes were equal in size, quality, and information about molecular pathology. There was no difference in procedural-related bleeding between the groups (p=0.847). Compared to forceps biopsies, cryobiopsies had a superior overall diagnostic yield (75.9% vs. 48.1%, p=0.001) and were better suited for further molecular analysis (p=0.001). The 1.1 mm and 1.7 mm cryoprobes displayed comparable diagnostic yield, ability to provide molecular pathology information, and safety. Forceps biopsy was inferior to cryobiopsy in all aspects except safety.

Lung Cancer
University Hospital of Zurich (CH), Spital Uster (CH)
Openalex Percentile: Top 63%
Medical Imaging and Pathology Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.