Optimized algorithm for speed-of-sound-based infant sulfur hexafluoride multiple-breath washout measurements

<bold>Introduction</bold> - Methodological issues with the existing algorithm (WBreath) used for the analysis of molar mass-based infant sulfur hexafluoride (SF6) multiple-breath washout (MBW) measurements can lead to implausible results and complicate the comparison between different age groups and centers. <bold>Methods</bold> - We developed an optimized algorithm for speed-of-sound-based infant SF6 MBW measurements (OASIS). This algorithm uses known context of the measurements to replace the dependence of WBreath on model input parameters. We validated the functional residual capacity (FRC) measurement accuracy of this new algorithm in vitro, and investigated its use in existing MBW datasets from different infant cohorts from Switzerland and South Africa. <bold>Results</bold> - In vitro, OASIS managed to outperform WBreath at FRC measurement accuracy, lowering mean (SD) absolute error from 5.1 (3.2) % to 2.1 (1.6) % across volumes relevant for the infant age range (n = 60, p < 0.001), in variable temperature, respiratory rate, tidal volume and ventilation inhomogeneity conditions. OASIS produced more plausible results than WBreath in longitudinal tracking of lung clearance index (LCI) in infants with cystic fibrosis, reducing average absolute differences between measurements at 6 weeks, 1 year and 6 years from 38.3 (16.2) % to 11.8 (6.5) % (n = 21, p < 0.001). OASIS also reduced differences in mean LCI between centers from 16.7 % to 2.1 % in healthy 6-week-old infants. <bold>Discussion</bold> - This new algorithm represents a meaningful advance in obtaining results from a legacy system of lung function measurement by allowing a single method to analyze measurements from different age groups and centers.

Authors

Institutions

Publication Details

Published
2024-09-14
DOI
https://doi.org/10.1183/13993003.congress-2024.oa4662
Citations
1
Primary Topic
Respiratory viral infections research
Type
article
Field-Weighted Citation Impact
0.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimized algorithm for speed-of-sound-based infant sulfur hexafluoride multiple-breath washout measurements

Carvern Jacobs, Philipp Latzin, Marc‐Alexander Oestreich, Thuvarakha Manogaran et al.
1 citations
Respiratory viral infections research
0.39
article

Optimized algorithm for speed-of-sound-based infant sulfur hexafluoride multiple-breath washout measurements

Carvern Jacobs, Philipp Latzin, Marc‐Alexander Oestreich, Thuvarakha Manogaran, Sophie Yammine, Ruth Steinberg, Diane Gray, Shaakira Chaya, Noëmi Künstle, Urs Frey, Carla Rebeca Da Silva Sena, Anne‐Christianne Kentgens, Florian Wyler, Olga Gorlanova, Yasmin Salem, Nathalie Monney
article en
1 citations

Abstract

<bold>Introduction</bold> - Methodological issues with the existing algorithm (WBreath) used for the analysis of molar mass-based infant sulfur hexafluoride (SF6) multiple-breath washout (MBW) measurements can lead to implausible results and complicate the comparison between different age groups and centers. <bold>Methods</bold> - We developed an optimized algorithm for speed-of-sound-based infant SF6 MBW measurements (OASIS). This algorithm uses known context of the measurements to replace the dependence of WBreath on model input parameters. We validated the functional residual capacity (FRC) measurement accuracy of this new algorithm in vitro, and investigated its use in existing MBW datasets from different infant cohorts from Switzerland and South Africa. <bold>Results</bold> - In vitro, OASIS managed to outperform WBreath at FRC measurement accuracy, lowering mean (SD) absolute error from 5.1 (3.2) % to 2.1 (1.6) % across volumes relevant for the infant age range (n = 60, p < 0.001), in variable temperature, respiratory rate, tidal volume and ventilation inhomogeneity conditions. OASIS produced more plausible results than WBreath in longitudinal tracking of lung clearance index (LCI) in infants with cystic fibrosis, reducing average absolute differences between measurements at 6 weeks, 1 year and 6 years from 38.3 (16.2) % to 11.8 (6.5) % (n = 21, p < 0.001). OASIS also reduced differences in mean LCI between centers from 16.7 % to 2.1 % in healthy 6-week-old infants. <bold>Discussion</bold> - This new algorithm represents a meaningful advance in obtaining results from a legacy system of lung function measurement by allowing a single method to analyze measurements from different age groups and centers.

University Hospital of Bern (CH), University Children’s Hospital Basel (CH), Red Cross War Memorial Children's Hospital (ZA)
Openalex Percentile: Top 32%
Respiratory viral infections research
0.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.