The final results of European external quality control program for laboratory testing of alpha1-antitrypsin deficiency (AATD EARCO LABNet) 2019-2022

Alpha1-antitrypsin deficiency (AATD), despite being one of the most common rare metabolic disorders, is frequently under/misdiagnosed. Accurate laboratory testing using validated methods is crucial for establishing clinical diagnosis, adjusting therapeutic decisions and preventive measures. To ensure high quality of biochemical and genetic testing for AATD we have established the European external quality assessment (EQA), which has been implemented in 7 leading European laboratories during 2019-2022. EQA consisted of 6 rounds. Coordinating centers provided 5-6 blinded reference materials of serum and dried blood spots (DBS) comprising normal and AAT deficient samples. Samples were processed and analyzed according to the site’s routine diagnostic protocols, including AAT concentration, phenotype and/or genotype assessment. Reported results were verified by the referral lab. The reported AAT concentrations in serum and DBS demonstrated mean deviation rates of 9.6-15.4% and 7.9-43.0%, respectively, across rounds. Results of pheno/genotyping assays in samples with common <italic>SERPINA1</italic> deficient variants (Z,S) all had an almost perfect interrater agreement (k>0.81) among labs. There were significant discrepancies for rare variants detection (k=0,7622 and 0,7703 for pheno/genotyping, respectively). The EQA results showed an exemplary interlaboratory concordance in common deficiency variants detection and highlighted the issue of identification and reporting of rare <italic>SERPINA1</italic> variants. Differences observed in DBS-based AAT concentration evaluation may indicate the need to refine the methodology. Unrestrictive grant support by CSL Behring and Grifols.

Authors

Institutions

Publication Details

Published
2024-09-14
DOI
https://doi.org/10.1183/13993003.congress-2024.pa359
Primary Topic
Protease and Inhibitor Mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The final results of European external quality control program for laboratory testing of alpha1-antitrypsin deficiency (AATD EARCO LABNet) 2019-2022

Tomás P. Carroll, Adriana Roży, Angelo Guido Corsico, Magdalena Pelc et al.
Protease and Inhibitor Mechanisms
article

The final results of European external quality control program for laboratory testing of alpha1-antitrypsin deficiency (AATD EARCO LABNet) 2019-2022

Tomás P. Carroll, Adriana Roży, Angelo Guido Corsico, Magdalena Pelc, Maria Cristina Monti, Noel Gerry Mcelvaney, Susana Seixas, Francisco Rodríguez‐Frias, Ilaria Ferrarotti, Marie‐Françoise Odou, Farid Zerimech, Marc Miravitlles, Timm Greulich, Irene Belmonte, Stefania Ottaviani, Malika Balduyck, Joanna Chorostowska‐Wynimko, Martina Veith
article en

Abstract

Alpha1-antitrypsin deficiency (AATD), despite being one of the most common rare metabolic disorders, is frequently under/misdiagnosed. Accurate laboratory testing using validated methods is crucial for establishing clinical diagnosis, adjusting therapeutic decisions and preventive measures. To ensure high quality of biochemical and genetic testing for AATD we have established the European external quality assessment (EQA), which has been implemented in 7 leading European laboratories during 2019-2022. EQA consisted of 6 rounds. Coordinating centers provided 5-6 blinded reference materials of serum and dried blood spots (DBS) comprising normal and AAT deficient samples. Samples were processed and analyzed according to the site’s routine diagnostic protocols, including AAT concentration, phenotype and/or genotype assessment. Reported results were verified by the referral lab. The reported AAT concentrations in serum and DBS demonstrated mean deviation rates of 9.6-15.4% and 7.9-43.0%, respectively, across rounds. Results of pheno/genotyping assays in samples with common <italic>SERPINA1</italic> deficient variants (Z,S) all had an almost perfect interrater agreement (k>0.81) among labs. There were significant discrepancies for rare variants detection (k=0,7622 and 0,7703 for pheno/genotyping, respectively). The EQA results showed an exemplary interlaboratory concordance in common deficiency variants detection and highlighted the issue of identification and reporting of rare <italic>SERPINA1</italic> variants. Differences observed in DBS-based AAT concentration evaluation may indicate the need to refine the methodology. Unrestrictive grant support by CSL Behring and Grifols.

Hebron University (PS), Philipps University of Marburg (DE), University of Pavia (IT), Beaumont Hospital (IE), Masih Daneshvari Hospital (IR), National Center for Tuberculosis and Lung Disease (GE), Vall d'Hebron Hospital Universitari (ES), Policlinico San Matteo Fondazione (IT), i3S - Instituto de Investigação e Inovação em Saúde, Universidade do Porto (PT), Institut de Biologie de Lille (FR)
Partnerships for the goals
Openalex Percentile: Top 71%
Protease and Inhibitor Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.