Diagnostic accuracy of Xpert MTB/RIF Ultra in bronchial aspirate specimens for microbiological confirmation of pulmonary tuberculosis in patients with negative smear and Xpert MTB/RIF Ultra results in sputum

<bold>Introduction:</bold> Worldwide up to one third of pulmonary tuberculosis (PTB) patients missed microbiological confirmation. Assessment of specimens obtained during bronchoscopy is one of the well-recognised methods to increase rate of microbiological confirmation in PTB. The data on diagnostic accuracy of Xpert MTB/RIF Ultra in bronchial aspirate (BA) specimen are very limited. <bold>Aim:</bold> To evaluated diagnostic accuracy of Xpert MTB/RIF Ultra in BA in patients with negative smear microscopy and Xpert MTB/RIF Ultra in sputum. <bold>Methods:</bold> We retrospectively reviewed microbiological and basic clinical characteristics of all patients who were consulted for suspected PTB at the Institute of Phthisiopneumology in Moldova during 2022 and had both negative smear and Xpert MTB/RIF Ultra results in sputum and in whom BA was obtained through bronchoscopy for further examination by Xpert MTB/RIF Ultra and culture for <italic>M. tuberculosis.</italic> <bold>Results:</bold> 393 cases with complete dataset have been analysed, of them 80 have been diagnosed with PTB. Positive culture for <italic>M. tuberculosis</italic> was obtained in 2.5% (10/393), smear microscopy was positive in 1.8% (7/393) and Xpert MTB/RIF Ultra in 2.3% (9/393) of BAs. The sensitivity and specificity of Xpert MTB/RIF Ultra in BA, using culture as reference standard, were correspondingly 80.0% (95%CI, 37.5% – 99.0%) and 98.7% (95%CI, 97.0% - 99.4%). Rapid microbiological confirmation of PTB was obtained in 11.2% (9/80) of the patients diagnosed with PTB. <bold>Conclusion:</bold> Xpert MTB/RIF Ultra has a good diagnostic accuracy in BA samples in patients with extremely paucibacillary sputum.

Authors

Institutions

Publication Details

Published
2024-09-14
DOI
https://doi.org/10.1183/13993003.congress-2024.pa636
Primary Topic
Lung Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic accuracy of Xpert MTB/RIF Ultra in bronchial aspirate specimens for microbiological confirmation of pulmonary tuberculosis in patients with negative smear and Xpert MTB/RIF Ultra results in sputum

Alexandru Codreanu, Nelly Ciobanu, Elena Chesov, Valeriu Crudu et al.
Lung Cancer Diagnosis and Treatment
article

Diagnostic accuracy of Xpert MTB/RIF Ultra in bronchial aspirate specimens for microbiological confirmation of pulmonary tuberculosis in patients with negative smear and Xpert MTB/RIF Ultra results in sputum

Alexandru Codreanu, Nelly Ciobanu, Elena Chesov, Valeriu Crudu, Christoph Lange, Dumitru Chesov, Valentina Polevoi
article en

Abstract

<bold>Introduction:</bold> Worldwide up to one third of pulmonary tuberculosis (PTB) patients missed microbiological confirmation. Assessment of specimens obtained during bronchoscopy is one of the well-recognised methods to increase rate of microbiological confirmation in PTB. The data on diagnostic accuracy of Xpert MTB/RIF Ultra in bronchial aspirate (BA) specimen are very limited. <bold>Aim:</bold> To evaluated diagnostic accuracy of Xpert MTB/RIF Ultra in BA in patients with negative smear microscopy and Xpert MTB/RIF Ultra in sputum. <bold>Methods:</bold> We retrospectively reviewed microbiological and basic clinical characteristics of all patients who were consulted for suspected PTB at the Institute of Phthisiopneumology in Moldova during 2022 and had both negative smear and Xpert MTB/RIF Ultra results in sputum and in whom BA was obtained through bronchoscopy for further examination by Xpert MTB/RIF Ultra and culture for <italic>M. tuberculosis.</italic> <bold>Results:</bold> 393 cases with complete dataset have been analysed, of them 80 have been diagnosed with PTB. Positive culture for <italic>M. tuberculosis</italic> was obtained in 2.5% (10/393), smear microscopy was positive in 1.8% (7/393) and Xpert MTB/RIF Ultra in 2.3% (9/393) of BAs. The sensitivity and specificity of Xpert MTB/RIF Ultra in BA, using culture as reference standard, were correspondingly 80.0% (95%CI, 37.5% – 99.0%) and 98.7% (95%CI, 97.0% - 99.4%). Rapid microbiological confirmation of PTB was obtained in 11.2% (9/80) of the patients diagnosed with PTB. <bold>Conclusion:</bold> Xpert MTB/RIF Ultra has a good diagnostic accuracy in BA samples in patients with extremely paucibacillary sputum.

Phthisiopneumology Institute "Chiril Draganiuc" (MD), Nicolae Testemițanu State University of Medicine and Pharmacy (MD), Research Center Borstel - Leibniz Lung Center (DE)
Good health and well-being
Openalex Percentile: Top 63%
Lung Cancer Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.