GCN-LSTM Based Transient Angle Stability Assessment Method for Future Power Systems Considering Spatial-Temporal Disturbance Response Characteristics

Traditional transient angle stability analysis methods do not fully consider the spatial characteristics of the network topology and the temporal characteristics of the time-series disturbance. Hence, a data-driven method is proposed in this study, combining graph convolution network and long short-term memory network (GCN-LSTM) to analyze the transient power angle stability by exploring the spatiotemporal disturbance characteristics of future power systems with high penetration of renewable energy sources (wind and solar energy) and power electronics. The key time-series electrical state quantities are considered as the initial input feature quantities and normalized using the Z-score, whereas the network adjacency matrix is constructed according to the system network topology. The normalized feature quantities and network adjacency matrix were used as the inputs of the GCN to obtain the spatial features, reflecting changes in the network topology. Subsequently, the spatial features are inputted into the LSTM network to obtain the temporal features, reflecting dynamic changes in the transient power angle of the generators. Finally, the spatiotemporal features are fused through a fully connected network to analyze the transient power angle stability of future power systems, and the softmax activation cross-entropy loss functions are used to predict the stability of the samples. The proposed transient power angle stability assessment method is tested on a 500 kV AC-DC practical power system, and the simulation results show that the proposed method could effectively mine the spatiotemporal disturbance characteristics of power systems. Moreover, the proposed model has higher accuracy, higher recall rate, and shorter training and testing times than traditional transient power angle stability algorithms.

Authors

Institutions

Publication Details

Journal
Protection and Control of Modern Power Systems
Published
2024-11-01
DOI
https://doi.org/10.23919/pcmp.2023.000116
Citations
30
Primary Topic
Power System Optimization and Stability
Type
article
Field-Weighted Citation Impact
6.26

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

GCN-LSTM Based Transient Angle Stability Assessment Method for Future Power Systems Considering Spatial-Temporal Disturbance Response Characteristics

Ziqing Zhu, Ning Zhou, Chenhui Zhang, Zhenqiang Ma et al.
30 citations
Protection and Control of Modern Power Systems
Power System Optimization and Stability
6.26
article

GCN-LSTM Based Transient Angle Stability Assessment Method for Future Power Systems Considering Spatial-Temporal Disturbance Response Characteristics

Ziqing Zhu, Ning Zhou, Chenhui Zhang, Zhenqiang Ma, Linlin Ma, Yahan Li, Shiwei Xia, Gengyin Li
article en
30 citations

Abstract

Traditional transient angle stability analysis methods do not fully consider the spatial characteristics of the network topology and the temporal characteristics of the time-series disturbance. Hence, a data-driven method is proposed in this study, combining graph convolution network and long short-term memory network (GCN-LSTM) to analyze the transient power angle stability by exploring the spatiotemporal disturbance characteristics of future power systems with high penetration of renewable energy sources (wind and solar energy) and power electronics. The key time-series electrical state quantities are considered as the initial input feature quantities and normalized using the Z-score, whereas the network adjacency matrix is constructed according to the system network topology. The normalized feature quantities and network adjacency matrix were used as the inputs of the GCN to obtain the spatial features, reflecting changes in the network topology. Subsequently, the spatial features are inputted into the LSTM network to obtain the temporal features, reflecting dynamic changes in the transient power angle of the generators. Finally, the spatiotemporal features are fused through a fully connected network to analyze the transient power angle stability of future power systems, and the softmax activation cross-entropy loss functions are used to predict the stability of the samples. The proposed transient power angle stability assessment method is tested on a 500 kV AC-DC practical power system, and the simulation results show that the proposed method could effectively mine the spatiotemporal disturbance characteristics of power systems. Moreover, the proposed model has higher accuracy, higher recall rate, and shorter training and testing times than traditional transient power angle stability algorithms.

Protection and Control of Modern Power SystemsVol. 9(6)
Hong Kong Baptist University (HK), North China Electric Power University (CN), State Grid Corporation of China (China) (CN)
National Key Research and Development Program of China
Climate action
Openalex Percentile: Top 3%
Power System Optimization and Stability
6.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.