Surgical Aortic Valve Replacement Using a Supra-Annular Self-Expanding Bioprosthesis

The transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve has shown better hemodynamic outcomes and better valve durability at 5 years when compared with a surgical aortic valve replacement (SAVR). It is possible that the benefits of a self-expanding supra-annular valve can be achieved using a surgical approach. An Evolut (Medtronic) transcatheter aortic valve was surgically implanted in 4 patients undergoing SAVR. Standard surgical methods were used. Three patients had native aortic valve disease, and 1 patient had a degenerated surgical bioprosthesis. The measured valve size was 21 mm in 3 patients and 23 mm in 1 patient; all received a 29-mm Evolut. No valve migration was observed. No patients required a pacemaker. Discharge echocardiography showed low aortic valve gradients (arithmetic mean of 5.3 mm Hg). One patient had a mild paravalvular leak. SAVR using a self-expanding supra-annular valve can be successfully performed in patients not amenable to TAVR.

Authors

Institutions

Publication Details

Journal
JACC Case Reports
Published
2024-11-01
DOI
https://doi.org/10.1016/j.jaccas.2024.102664
Citations
1
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Surgical Aortic Valve Replacement Using a Supra-Annular Self-Expanding Bioprosthesis

Daniel O’Hair, Molly G. Ware, Srinivas Iyengar
1 citations
JACC Case Reports
Cardiac Valve Diseases and Treatments
0.40
article

Surgical Aortic Valve Replacement Using a Supra-Annular Self-Expanding Bioprosthesis

Daniel O’Hair, Molly G. Ware, Srinivas Iyengar
article en
1 citations

Abstract

The transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve has shown better hemodynamic outcomes and better valve durability at 5 years when compared with a surgical aortic valve replacement (SAVR). It is possible that the benefits of a self-expanding supra-annular valve can be achieved using a surgical approach. An Evolut (Medtronic) transcatheter aortic valve was surgically implanted in 4 patients undergoing SAVR. Standard surgical methods were used. Three patients had native aortic valve disease, and 1 patient had a degenerated surgical bioprosthesis. The measured valve size was 21 mm in 3 patients and 23 mm in 1 patient; all received a 29-mm Evolut. No valve migration was observed. No patients required a pacemaker. Discharge echocardiography showed low aortic valve gradients (arithmetic mean of 5.3 mm Hg). One patient had a mild paravalvular leak. SAVR using a self-expanding supra-annular valve can be successfully performed in patients not amenable to TAVR.

JACC Case ReportsVol. 29(21)
Boulder Community Hospital (US)
Openalex Percentile: Top 31%
Cardiac Valve Diseases and Treatments
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.