Numerical simulations of high-frequency ventilation in the presence of airway and lung tissue heterogeneities
<bold>Introduction:</bold> Whilst high-frequency ventilation (HFV) is widely used, it is mostly recommended in homogeneous lungs. Our aim was to evaluate the efficiency of pressure and volume transfer from the airway opening to a heterogeneous alveolar compartment in a simulation model of HFV. <bold>Methods:</bold> We created a numerical simulation based on <italic>in-vivo</italic> data from a porcine model with measurements at the airway opening (<italic>p</italic><sub>ao</sub>) and at the lung periphery using alveolar capsules (<italic>p</italic><sub>alv</sub>). Simulations assume a 5-Hz oscillation frequency in a model consisting of an endotracheal tube in series with a parallel impedance network of branches including an airway, a chest wall and a lung tissue compartment of variable inhomogeneity (set as a factor of 5 between extreme branches). Each branch comprises an airway resistance (<italic>R</italic><sub>aw</sub>), inertance and constant-phase tissue impedance (<italic>Z</italic><sub>ti</sub>). <bold>Results:</bold> The simulations yield <italic>p</italic><sub>alv</sub>/<italic>p</italic><sub>ao</sub> in good agreement with in vivo results and show that increasing net <italic>R</italic><sub>aw</sub> from 2 to 10 cmH<sub>2</sub>O⋅s/l reduces palv/pao from 0.155 to 0.098, respectively. With heterogeneity in <italic>R</italic><sub>aw</sub>, these <italic>R</italic><sub>aw</sub> changes increase the relative difference in regional <italic>p</italic><sub>alv</sub>/<italic>p</italic><sub>ao</sub> (112% to 328% at 2 to 10 cmH<sub>2</sub>O⋅s/l of net <italic>R</italic><sub>aw</sub>, respectively) and in regional tidal volume (VT<sub>r</sub>) (111% to 328%). With heterogeneity in <italic>R</italic><sub>aw</sub>, a 2.5-fold increase in <italic>Z</italic><sub>ti</sub> reduces the relative difference in <italic>p</italic><sub>alv</sub>/<italic>p</italic><sub>ao</sub> between extreme branches from 206% to 75%, and reduces VT<sub>r</sub> from 205% to 74%. <bold>Conclusion:</bold> Our simulation validated by <italic>in-vivo</italic> data allows predictions of net and regional alveolar pressure and volume distribution, contributing to the understanding of HFV in the presence of ventilation heterogeneities. <bold>Funding:</bold> OTKA-NKFIH K138032 and FK134274
Authors
- Gergely H. Fodor (ORCID: https://orcid.org/0000-0002-4736-4966)
- Álmos Schranc (ORCID: https://orcid.org/0000-0002-9955-9116)
- Walid Habre (ORCID: https://orcid.org/0000-0002-6521-5091)
- Péter Makra
- Roberta Südy (ORCID: https://orcid.org/0000-0003-0080-7616)
- Ferenc Peták (ORCID: https://orcid.org/0000-0001-6249-9327)
Institutions
- University of Geneva (CH)
- University of Szeged (HU)
Publication Details
- Published
- 2024-09-14
- DOI
- https://doi.org/10.1183/13993003.congress-2024.pa2601
- Primary Topic
- Respiratory Support and Mechanisms
- Type
- article
- Field-Weighted Citation Impact
- 0.00