Does Use Of A Heat and Moisture Exchanger Affect pMDI Delivery to a Simulated Patient on Mechanical Ventilation
<bold>Objective:</bold> Heat and moisture exchangers (HME) have been designed to allow aerosol delivery to mechanically ventilated patients by bypassing the HME during aerosol administration. This study evaluates the effect a bypass-type HME has on aerosol delivery in a simulated adult ventilator setting. <bold>Methods:</bold> A Fisher & Paykel RT210 adult breathing circuit was used to simulate an adult model (500mL, duty cycle = 33%, 13 bpm) generated using a Draeger Infinity C500 ventilator. A Gibeck Humid-Flo HME was placed at the entrance to an 8.0mm diameter endotracheal tube (ETT). An aerosol collection filter was located at the distal end of the ETT and coupled to a SelfTestLung, simulating the patient. 5 actuations of Ventolin pMDI were delivered through 3 different delivery devices and a built-in port adapter in the circuit, followed by 6 complete breathing cycles. Salbutamol assay was undertaken by HPLC-UV. Comparisons were made on potential dose to the lungs and were equated to a potential relative carbon footprint based upon published claims [1] for Ventolin. <bold>Results:</bold> <bold>Conclusions:</bold> This study has shown that use of a bypass-type HME can allow delivery of medication to the patient. It also demonstrates that use of AeroChamber* VENT HC spacer could potentially reduce the carbon footprint by up to 4-fold compared to the alternative options. By maximizing the amount of each puff reaching the lungs the patient is likely to get relief sooner and reduce the number of puffs needed. <table-wrap><object-id>erj;64/suppl_68/PA2613/TB1</object-id><object-id>T1</object-id><object-id>TB1</object-id><table><colgroup><col></col><col></col></colgroup><tbody><tr><td>Device</td><td>Total Mass of Salbutamol /Actuation (mean ± SD)</td></tr><tr><td>AeroChamber* VENT HC</td><td>33.1±2.7µg</td></tr><tr><td>Spirale DDS</td><td>7.7±3.0µg</td></tr><tr><td>Hudson RCI MDI Adaptor</td><td>20.2±3.9µg</td></tr><tr><td>Built-in circuit pMDI port</td><td>22.9±1.2µg</td></tr></tbody></table></table-wrap> [1] https://greeninhaler.org
Authors
- Mark Nagel
- Cathy Doyle (ORCID: https://orcid.org/0000-0002-8657-9038)
- Jason Suggett (ORCID: https://orcid.org/0000-0003-0026-7242)
- Rubina Ali
Institutions
- Trudell Medical International (Canada) (CA)
Publication Details
- Published
- 2024-09-14
- DOI
- https://doi.org/10.1183/13993003.congress-2024.pa2613
- Primary Topic
- Respiratory Support and Mechanisms
- Type
- article
- Field-Weighted Citation Impact
- 0.00