Is the impedance modulus (Z) an adequate summary of oscillometry parameters in the general population?

<bold>Background:</bold> Oscillometry measures the respiratory system's resistance (R) and reactance (X). The modulus of the impedance (Z), combining both R and X, may represent a single, simple, and more comprehensible measure of the condition of the respiratory system. <bold>Aims:</bold> To compare the association of abnormal resistance, reactance and modulus of impedance with respiratory symptoms and respiratory diseases in a general adult population. <bold>Methods:</bold> We included 8184 subjects (mean age=48y, Females=52%) of the Austrian LEAD general population cohort. Resistance (R), reactance (X), and the modulus of the impedance (Z) at 5 Hz were measured by oscillometry (Resmon Pro Full, Restech, Italy). On the same day, respiratory symptoms and diseases were assessed by a questionnaire. Abnormal parameters were defined according to Veneroni et al., ERS2023. We computed the risk ratios of presenting symptoms and/or disease for subjects with 1) an abnormal Z, 2) abnormal R or X, 3) abnormal R, and 4) abnormal X. <bold>Results:</bold> Performances were similar among the different oscillometry parameters. The number of subjects with abnormal R or X and Z were different (Figure). <fig><object-id>erj;64/suppl_68/PA3056/F1</object-id><object-id>F1</object-id><object-id>F1</object-id><graphic></graphic></fig> <bold>Conclusions:</bold> Our results suggest that X is more sensitive to the onset of symptoms, but Z provides a single measure that adequately represents lung pathophysiology.

Authors

Institutions

Publication Details

Published
2024-09-14
DOI
https://doi.org/10.1183/13993003.congress-2024.pa3056
Primary Topic
Body Composition Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Is the impedance modulus (Z) an adequate summary of oscillometry parameters in the general population?

Pasquale Pio Pompilio, Robab Breyer‐Kohansal, Marie‐Kathrin Breyer, Chiara Veneroni et al.
Body Composition Measurement Techniques
article

Is the impedance modulus (Z) an adequate summary of oscillometry parameters in the general population?

Pasquale Pio Pompilio, Robab Breyer‐Kohansal, Marie‐Kathrin Breyer, Chiara Veneroni, Raffaele L. Dellacá, Alessandro Gobbi, Emiel F.�M. Wouters, Christoph Gross, Sylvia Hartl, Charles G. Irvin, Christoph Valach
article en

Abstract

<bold>Background:</bold> Oscillometry measures the respiratory system's resistance (R) and reactance (X). The modulus of the impedance (Z), combining both R and X, may represent a single, simple, and more comprehensible measure of the condition of the respiratory system. <bold>Aims:</bold> To compare the association of abnormal resistance, reactance and modulus of impedance with respiratory symptoms and respiratory diseases in a general adult population. <bold>Methods:</bold> We included 8184 subjects (mean age=48y, Females=52%) of the Austrian LEAD general population cohort. Resistance (R), reactance (X), and the modulus of the impedance (Z) at 5 Hz were measured by oscillometry (Resmon Pro Full, Restech, Italy). On the same day, respiratory symptoms and diseases were assessed by a questionnaire. Abnormal parameters were defined according to Veneroni et al., ERS2023. We computed the risk ratios of presenting symptoms and/or disease for subjects with 1) an abnormal Z, 2) abnormal R or X, 3) abnormal R, and 4) abnormal X. <bold>Results:</bold> Performances were similar among the different oscillometry parameters. The number of subjects with abnormal R or X and Z were different (Figure). <fig><object-id>erj;64/suppl_68/PA3056/F1</object-id><object-id>F1</object-id><object-id>F1</object-id><graphic></graphic></fig> <bold>Conclusions:</bold> Our results suggest that X is more sensitive to the onset of symptoms, but Z provides a single measure that adequately represents lung pathophysiology.

Sigmund Freud Privatuniversität Wien (AT), University of Vermont (US), Maastricht University (NL), Klinik Hietzing (AT), Sigmund Freud Privatuniversität - Standort Mailand (IT), Ludwig Boltzmann Institute for Lung Vascular Research (AT), ResilTech (Italy) (IT), Politecnico di Milano (IT)
Openalex Percentile: Top 72%
Body Composition Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.