Variable reliability of the (1,3)-β-<scp>d</scp>-glucan test for screening <i>Pneumocystis</i> pneumonia in HIV-negative patients depending on the underlying condition

(1,3)-β-d-Glucan (BG) assay is a non-invasive test commonly used in the diagnostic of invasive fungal diseases. Given its high sensitivity, it was suggested that a negative BG result is sufficient for excluding the diagnosis of Pneumocystis pneumonia (PCP). However, suboptimal performance has been described in human immunodeficiency virus (HIV)-negative patients, particularly those with haematological malignancies. We aimed to assess the sensitivity of the BG assay for diagnosing PCP in HIV-negative patients based on their underlying PCP risk factors. We conducted a single-center, retrospective study (2009-2021) enrolling HIV-negative patients diagnosed with PCP and who underwent BG testing. Patients colonized with Pneumocystis jirovecii were included as a control group. In all, 55 PCP patients and 61 colonized patients met the inclusion criteria. Patients were further categorized according to the underlying condition that exposes patients to PCP. Median BG concentration was significantly higher in the PCP group than in the colonization group (500 vs. 31 pg/ml; P < 10-4, Mann-Whitney test) and the BG assay demonstrated a sensitivity of 85% and a specificity of 82% for PCP diagnosis. Notably, sensitivity was significantly higher in non-cancer patients (100%) compared to those with solid cancer (72%) and haematologic cancer (79%) (P < .05, Fischer's exact test). These findings strengthen the high performance of BG testing for screening PCP in non-cancer patients, comparable to that observed in HIV-infected individuals. In contrast, they highlight its low reliability in patients with malignancies, emphasizing the importance of considering underlying conditions when interpreting BG results and refining the role of the test in PCP diagnosis.

Authors

Institutions

Publication Details

Journal
Medical Mycology
Published
2024-11-01
DOI
https://doi.org/10.1093/mmy/myae106
Primary Topic
Pneumocystis jirovecii pneumonia detection and treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Variable reliability of the (1,3)-β-d-glucan test for screening Pneumocystis pneumonia in HIV-negative patients depending on the underlying condition

Anne Totet, Yohann Le Govic, Céline Damiani, Eric Kostka
Medical Mycology
Pneumocystis jirovecii pneumonia detection and treatment
article

Variable reliability of the (1,3)-β-d-glucan test for screening Pneumocystis pneumonia in HIV-negative patients depending on the underlying condition

Anne Totet, Yohann Le Govic, Céline Damiani, Eric Kostka
article en

Abstract

(1,3)-β-d-Glucan (BG) assay is a non-invasive test commonly used in the diagnostic of invasive fungal diseases. Given its high sensitivity, it was suggested that a negative BG result is sufficient for excluding the diagnosis of Pneumocystis pneumonia (PCP). However, suboptimal performance has been described in human immunodeficiency virus (HIV)-negative patients, particularly those with haematological malignancies. We aimed to assess the sensitivity of the BG assay for diagnosing PCP in HIV-negative patients based on their underlying PCP risk factors. We conducted a single-center, retrospective study (2009-2021) enrolling HIV-negative patients diagnosed with PCP and who underwent BG testing. Patients colonized with Pneumocystis jirovecii were included as a control group. In all, 55 PCP patients and 61 colonized patients met the inclusion criteria. Patients were further categorized according to the underlying condition that exposes patients to PCP. Median BG concentration was significantly higher in the PCP group than in the colonization group (500 vs. 31 pg/ml; P < 10-4, Mann-Whitney test) and the BG assay demonstrated a sensitivity of 85% and a specificity of 82% for PCP diagnosis. Notably, sensitivity was significantly higher in non-cancer patients (100%) compared to those with solid cancer (72%) and haematologic cancer (79%) (P < .05, Fischer's exact test). These findings strengthen the high performance of BG testing for screening PCP in non-cancer patients, comparable to that observed in HIV-infected individuals. In contrast, they highlight its low reliability in patients with malignancies, emphasizing the importance of considering underlying conditions when interpreting BG results and refining the role of the test in PCP diagnosis.

Medical MycologyVol. 62(11)
Centre Hospitalier Universitaire Amiens-Picardie (FR), Agents infectieux, résistance et chimiothérapie (FR), Université de Picardie Jules Verne (FR)
Good health and well-being
Openalex Percentile: Top 70%
Pneumocystis jirovecii pneumonia detection and treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines