Diagnostic value of SIFT-MS and GC-ToF-MS analysis of exhaled breath for asthma diagnosis in school-aged children

<bold>Background</bold> Asthma is a common chronic condition in childhood with a high rate of misdiagnosis. Development of non-invasive, reliable tests is crucial to enhance the current diagnostic approaches for asthma detection. Volatile organic compounds (VOC) in exhaled breath are promising potential biomarkers for asthma. <bold>Aim</bold> Comparison of the diagnostic accuracy of Selected Ion Flow Tube-Mass Spectrometry (SIFT-MS) and Gas Chromatography-Time of Flight-Mass Spectrometry (GC-ToF-MS) for distinguishing asthmatic from healthy school-aged children. <bold>Methods</bold> A cross-sectional study was performed in asthmatic and healthy school-aged children. Breath samples were analysed using SIFT-MS and GC-ToF-MS. Principal component analysis and unsupervised random forest models were used for exploratory data analysis. Classification models were built to evaluate the discriminatory power of both techniques. <bold>Results</bold> 51 asthmatic and 68 healthy school-aged children were included. The classification model built using SIFT-MS data resulted in an Area Under the Receiver Operating Characteristic (AUROC) curve value equal to 0.85 and in a sensitivity and specificity of 72.5% and 80.9%, respectively. Twenty-nine m/z ratios were identified showing the highest discrimination power. The classification model built using GC-ToF-MS data resulted in an AUROC curve value equal to 0.89 and in a sensitivity and specificity of 92.2% and 65.5%. Twenty-one discriminative variables were identified as those exhibiting the highest discrimination power. <bold>Conclusion</bold> SIFT-MS can be a reliable, user-friendly alternative to GC-ToF-MS, possibly paving the way for clinical applications of breath-based diagnosis in paediatric asthma.

Authors

Institutions

Publication Details

Published
2024-09-14
DOI
https://doi.org/10.1183/13993003.congress-2024.pa4053
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic value of SIFT-MS and GC-ToF-MS analysis of exhaled breath for asthma diagnosis in school-aged children

Michiel Bannier, Onno C. P. van Schayck, Sophie Kienhorst, Agnieszka Smolinska et al.
Advanced Chemical Sensor Technologies
article

Diagnostic value of SIFT-MS and GC-ToF-MS analysis of exhaled breath for asthma diagnosis in school-aged children

Michiel Bannier, Onno C. P. van Schayck, Sophie Kienhorst, Agnieszka Smolinska, Quirijn Jöbsis, Edward Dompeling, Raffaele Vitale, Moniek Van Aarle
article en

Abstract

<bold>Background</bold> Asthma is a common chronic condition in childhood with a high rate of misdiagnosis. Development of non-invasive, reliable tests is crucial to enhance the current diagnostic approaches for asthma detection. Volatile organic compounds (VOC) in exhaled breath are promising potential biomarkers for asthma. <bold>Aim</bold> Comparison of the diagnostic accuracy of Selected Ion Flow Tube-Mass Spectrometry (SIFT-MS) and Gas Chromatography-Time of Flight-Mass Spectrometry (GC-ToF-MS) for distinguishing asthmatic from healthy school-aged children. <bold>Methods</bold> A cross-sectional study was performed in asthmatic and healthy school-aged children. Breath samples were analysed using SIFT-MS and GC-ToF-MS. Principal component analysis and unsupervised random forest models were used for exploratory data analysis. Classification models were built to evaluate the discriminatory power of both techniques. <bold>Results</bold> 51 asthmatic and 68 healthy school-aged children were included. The classification model built using SIFT-MS data resulted in an Area Under the Receiver Operating Characteristic (AUROC) curve value equal to 0.85 and in a sensitivity and specificity of 72.5% and 80.9%, respectively. Twenty-nine m/z ratios were identified showing the highest discrimination power. The classification model built using GC-ToF-MS data resulted in an AUROC curve value equal to 0.89 and in a sensitivity and specificity of 92.2% and 65.5%. Twenty-one discriminative variables were identified as those exhibiting the highest discrimination power. <bold>Conclusion</bold> SIFT-MS can be a reliable, user-friendly alternative to GC-ToF-MS, possibly paving the way for clinical applications of breath-based diagnosis in paediatric asthma.

Centre National de la Recherche Scientifique (FR), Maastricht University Medical Centre (NL), Maastricht University (NL), Department of Health (TW), Laboratoire de Réactivité et Chimie des Solides (FR)
Zero hunger
Openalex Percentile: Top 82%
Advanced Chemical Sensor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.