Continuous measurements of respiratory muscle blood flow and oxygen consumption using non-invasive frequency domain near-infrared spectroscopy and diffuse correlation spectroscopy

Prior studies of muscle blood flow and muscle specific oxygen consumption have required invasive injection of dye and Magnetic Resonance Imaging, respectively. Such measures have limited utility for continuous monitoring of the respiratory muscles in patients. Frequency domain near-infrared spectroscopy and diffuse correlation spectroscopy (FD-NIRS & DCS) can provide continuous surrogate measures of blood flow index (BFi) and metabolic rate of oxygen consumption (MRO2). This study aimed to validate sternocleidomastoid (SCM) FD-NIRS & DCS outcomes against electromyography (EMG) and mouth pressure (Pm) during incremental inspiratory threshold loading (ITL). Six females and six male healthy adults (30±7 years, maximum inspiratory pressure 118±61 cmH2O) performed ITL with 50g increments every two minutes until task failure. FD-NIRS & DCS continuously measured SCM oxygenated and deoxygenated hemoglobin+myoglobin (oxy/deoxy[Hb+Mb]), tissue saturation of oxygen (StO2), BFi and MRO2. Ventilatory parameters (e.g., Pm) were also evaluated. Pm increased during incremental ITL (P<0.05), reaching -47[−74, -34] cmH2O at task failure. Ventilatory parameters were constant throughout ITL (P>0.05). SCM BFi and MRO2 increased from the start of the ITL (P<0.05). Deoxy[Hb+Mb] increased close to task failure, concomitantly with a plateau in BFi, a constant increase in MRO2, and decreased StO2. SCM deoxy[Hb+Mb], BFi, StO2 and MRO2 correlated with sternocleidomastoid EMG (P<0.05 for all). Increasing SCM oxygen consumption near task failure was associated with increased oxygen extraction while delivery plateaued and reduced StO2

Authors

Institutions

Publication Details

Published
2024-09-14
DOI
https://doi.org/10.1183/13993003.congress-2024.pa4133
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Continuous measurements of respiratory muscle blood flow and oxygen consumption using non-invasive frequency domain near-infrared spectroscopy and diffuse correlation spectroscopy

Dmitry Rozenberg, Peter Rassam, Antenor Rodrigues, Ewan C. Goligher et al.
Non-Invasive Vital Sign Monitoring
article

Continuous measurements of respiratory muscle blood flow and oxygen consumption using non-invasive frequency domain near-infrared spectroscopy and diffuse correlation spectroscopy

Dmitry Rozenberg, Peter Rassam, Antenor Rodrigues, Ewan C. Goligher, Darren Roblyer, Kazuya Shingai, Laurent Brochard, W. Darlene Reid, Carlos A. Gómez
article en

Abstract

Prior studies of muscle blood flow and muscle specific oxygen consumption have required invasive injection of dye and Magnetic Resonance Imaging, respectively. Such measures have limited utility for continuous monitoring of the respiratory muscles in patients. Frequency domain near-infrared spectroscopy and diffuse correlation spectroscopy (FD-NIRS & DCS) can provide continuous surrogate measures of blood flow index (BFi) and metabolic rate of oxygen consumption (MRO2). This study aimed to validate sternocleidomastoid (SCM) FD-NIRS & DCS outcomes against electromyography (EMG) and mouth pressure (Pm) during incremental inspiratory threshold loading (ITL). Six females and six male healthy adults (30±7 years, maximum inspiratory pressure 118±61 cmH2O) performed ITL with 50g increments every two minutes until task failure. FD-NIRS & DCS continuously measured SCM oxygenated and deoxygenated hemoglobin+myoglobin (oxy/deoxy[Hb+Mb]), tissue saturation of oxygen (StO2), BFi and MRO2. Ventilatory parameters (e.g., Pm) were also evaluated. Pm increased during incremental ITL (P<0.05), reaching -47[−74, -34] cmH2O at task failure. Ventilatory parameters were constant throughout ITL (P>0.05). SCM BFi and MRO2 increased from the start of the ITL (P<0.05). Deoxy[Hb+Mb] increased close to task failure, concomitantly with a plateau in BFi, a constant increase in MRO2, and decreased StO2. SCM deoxy[Hb+Mb], BFi, StO2 and MRO2 correlated with sternocleidomastoid EMG (P<0.05 for all). Increasing SCM oxygen consumption near task failure was associated with increased oxygen extraction while delivery plateaued and reduced StO2

Boston University (US), St. Michael's Hospital (CA), University Health Network (CA), University of Toronto (CA)
Clean water and sanitation
Openalex Percentile: Top 82%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.