Bronchoscopic Lung Volume Reduction with Zephyr Valves: The French Real-world Experience

<bold>Background:</bold> BLVR with Zephyr valves (ZV) is a treatment option for patients with severe emphysema. Prospectively collected real-world data in France needed for health authorities and confirm RCT findings. <bold>Objective:</bold> Evaluate safety and effectiveness of the ZV treatment of patients with severe emphysema across treating centers in France with varying level of experience. <bold>Methods:</bold> Multi-center, single-arm, prospective registry at 11 centers. ZV placement performed per standard of care in France. <bold>Results:</bold> 154 patients (51% male; baseline mean±SD: Post-BD FEV1 29.6%±8.8; RV 251%±55 pred.) with a CV- target lobe enrolled. 93% had ZV placement during 2 procedures and 7% in a single procedure; median of 5 valves placed. Mean TLVR at 45days was -1.01L±0.74 with 79.9% of patients achieving ≥350ml reduction. At 12months, 48.4% patients were FEV1 responders (≥12% improvement); mean changes from baseline to 6- and 12-months respectively were: FEV1 +18.0%, +15.3%; RV −0.49L, −0.28L; SGRQ -8.8pts, -6.4pts; and 6MWD +24m, +25m. SAEs (>3%) in the treatment period (0 to 45days post-ZV), longer term (46days to 12months) include pneumothorax (11.0%, 5.0%) and COPD exacerbations (5.2%, 12.9%), respectively. Five (3.2%) deaths occurred. <bold>Conclusion:</bold> French real-world data of ZV benefits in severe emphysema patients is consistent with prior studies with clinically meaningful reduction in hyperinflation, improvements in lung function, exercise capacity and quality of life. In this single arm study, the pneumothorax rate after staged ZV implantation was consistent with recent retrospective published studies and appear to be lower than previously reported in RCTs, whereas the average number of valves placed was higher.

Authors

Institutions

Publication Details

Published
2024-09-14
DOI
https://doi.org/10.1183/13993003.congress-2024.pa4341
Primary Topic
Lung Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bronchoscopic Lung Volume Reduction with Zephyr Valves: The French Real-world Experience

Bruno Degano, Narinder S. Shargill, Christophe Gut‐Gobert, ARNAUD AB BOURDIN et al.
Lung Cancer Diagnosis and Treatment
article

Bronchoscopic Lung Volume Reduction with Zephyr Valves: The French Real-world Experience

Bruno Degano, Narinder S. Shargill, Christophe Gut‐Gobert, ARNAUD AB BOURDIN, Samy Lachkar, Nicolas Guibert, Armelle Marceau, Nicolas Favrolt, Thomas Egenod, F. Wallyn, Romain Kessler, Isabelle Court‐Fortune
article en

Abstract

<bold>Background:</bold> BLVR with Zephyr valves (ZV) is a treatment option for patients with severe emphysema. Prospectively collected real-world data in France needed for health authorities and confirm RCT findings. <bold>Objective:</bold> Evaluate safety and effectiveness of the ZV treatment of patients with severe emphysema across treating centers in France with varying level of experience. <bold>Methods:</bold> Multi-center, single-arm, prospective registry at 11 centers. ZV placement performed per standard of care in France. <bold>Results:</bold> 154 patients (51% male; baseline mean±SD: Post-BD FEV1 29.6%±8.8; RV 251%±55 pred.) with a CV- target lobe enrolled. 93% had ZV placement during 2 procedures and 7% in a single procedure; median of 5 valves placed. Mean TLVR at 45days was -1.01L±0.74 with 79.9% of patients achieving ≥350ml reduction. At 12months, 48.4% patients were FEV1 responders (≥12% improvement); mean changes from baseline to 6- and 12-months respectively were: FEV1 +18.0%, +15.3%; RV −0.49L, −0.28L; SGRQ -8.8pts, -6.4pts; and 6MWD +24m, +25m. SAEs (>3%) in the treatment period (0 to 45days post-ZV), longer term (46days to 12months) include pneumothorax (11.0%, 5.0%) and COPD exacerbations (5.2%, 12.9%), respectively. Five (3.2%) deaths occurred. <bold>Conclusion:</bold> French real-world data of ZV benefits in severe emphysema patients is consistent with prior studies with clinically meaningful reduction in hyperinflation, improvements in lung function, exercise capacity and quality of life. In this single arm study, the pneumothorax rate after staged ZV implantation was consistent with recent retrospective published studies and appear to be lower than previously reported in RCTs, whereas the average number of valves placed was higher.

Centre Hospitalier Universitaire de Lille (FR), CHU Dijon Bourgogne (FR), Hôpital Larrey (FR), Centre Hospitalier Régional Universitaire de Brest (FR), Groupe Hospitalier de l'Institut Catholique de Lille (FR), Hôpital Bichat-Claude-Bernard (FR), Hôpitaux Universitaires de Strasbourg (FR), Hôpital Arnaud de Villeneuve (FR), Pulmonx (United States) (US), Centre Hospitalier Universitaire de Saint-Étienne (FR), Hôpital Dupuytren (FR), Hôpital Maison Blanche (FR), Université de Rouen Normandie (FR), Université Grenoble Alpes (FR)
Openalex Percentile: Top 63%
Lung Cancer Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.