Objective versus subjective assessment of cough burden – proof-of-concept of an automated cough recorder

<bold>Introduction:</bold> The burden of cough can be assessed through subjective or objective measures. We present as proof-of-concept a novel AI-based continuous cough recording system. <bold>Methods:</bold> The cough recording system NELA (Carepath Technologies GmbH) consisting of 3 interconnected devices was installed at-home for 3 consecutive days. The data has not been used for training of NELAs algorithms. Postprocessing consisted of removing duplicates and retaining only cough sounds that belong to the respective patient. <bold>Results:</bold> The cohort consist of 241 patients with chronic cough (>8 weeks) (M<sub>age</sub>= 59.2, SD 20.5, male= 50.6); COPD (75), Asthma (83), RCC (45), chronic bronchitis (18) and ‘other disease’ (20), confirmed diagnosis in 67%. Performance of NELA for cough detection increased with the additional algorithm to assign cough to the individual patient (sensitivity 92.7 to 93.7%, specificity 95.8 to 96.7%). Average cough rate was 5.9 coughs/h. Cough rates differed significantly between disease types (M<sub>asthma</sub>=3.8 c/h, M<sub>COPD</sub>= 7.9 c/h, M<sub>RCC</sub>=6.1 c/h), Tukey's HSD post-hoc test showed significantly higher mean hourly cough rates in COPD patients compared to Asthma (p<.001, 95%CI [1.62, 6.69]). Self-reported cough frequency, reported as ‘often’ [n=168, range 7-686 total coughs] or ‘very often’ [n=68, 18-3905 coughs], did not result in significant different means for total cough event recorded (|t| (≈ 79.94) = -1.53, p=.13). <bold>Conclusion:</bold> This cohort illustrates the discrepancy between subjective and objective assessment of burden of cough and serves as a proof-of-concept of NELAs continuous, at-home, individual cough detection with high performance, across different respiratory diseases.

Authors

Institutions

Publication Details

Published
2024-09-14
DOI
https://doi.org/10.1183/13993003.congress-2024.pa5186
Primary Topic
Respiratory and Cough-Related Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Objective versus subjective assessment of cough burden – proof-of-concept of an automated cough recorder

Thomas Hering, Andrea Berten, Louise Otto, Satish Pant et al.
Respiratory and Cough-Related Research
article

Objective versus subjective assessment of cough burden – proof-of-concept of an automated cough recorder

Thomas Hering, Andrea Berten, Louise Otto, Satish Pant, N. Stenzel, Klaus Kenn
article en

Abstract

<bold>Introduction:</bold> The burden of cough can be assessed through subjective or objective measures. We present as proof-of-concept a novel AI-based continuous cough recording system. <bold>Methods:</bold> The cough recording system NELA (Carepath Technologies GmbH) consisting of 3 interconnected devices was installed at-home for 3 consecutive days. The data has not been used for training of NELAs algorithms. Postprocessing consisted of removing duplicates and retaining only cough sounds that belong to the respective patient. <bold>Results:</bold> The cohort consist of 241 patients with chronic cough (>8 weeks) (M<sub>age</sub>= 59.2, SD 20.5, male= 50.6); COPD (75), Asthma (83), RCC (45), chronic bronchitis (18) and ‘other disease’ (20), confirmed diagnosis in 67%. Performance of NELA for cough detection increased with the additional algorithm to assign cough to the individual patient (sensitivity 92.7 to 93.7%, specificity 95.8 to 96.7%). Average cough rate was 5.9 coughs/h. Cough rates differed significantly between disease types (M<sub>asthma</sub>=3.8 c/h, M<sub>COPD</sub>= 7.9 c/h, M<sub>RCC</sub>=6.1 c/h), Tukey's HSD post-hoc test showed significantly higher mean hourly cough rates in COPD patients compared to Asthma (p<.001, 95%CI [1.62, 6.69]). Self-reported cough frequency, reported as ‘often’ [n=168, range 7-686 total coughs] or ‘very often’ [n=68, 18-3905 coughs], did not result in significant different means for total cough event recorded (|t| (≈ 79.94) = -1.53, p=.13). <bold>Conclusion:</bold> This cohort illustrates the discrepancy between subjective and objective assessment of burden of cough and serves as a proof-of-concept of NELAs continuous, at-home, individual cough detection with high performance, across different respiratory diseases.

Chemnitz University of Technology (DE), Psychologische Hochschule Berlin (DE), Schön Klinik Berchtesgadener Land (DE), Berlin Heart (Germany) (DE), Medical Technologies (Czechia) (CZ)
Openalex Percentile: Top 64%
Respiratory and Cough-Related Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.