Comparison between standard 6 minutes field walk test and walking pad for functional evaluation in patients with chronic lung disease

<bold>Comparison between standard 6 minutes field walk test and walking pad for functional evaluation in patients with chronic lung disease</bold> <bold>BACKGROUND:</bold> The standard 6-minute field walk test (6MWT) is commonly used for functional evaluation in chronic obstructive pulmonary disease (COPD). However, its practicality is hindered by the requirement for a 30-meter hallway. Performing the test on a walking pad may enhance convenience, particularly in centers with limited space. <bold>OBJECTIVES:</bold> To compare the 6-minute walk distance (6MWD) by the standard hallway (HW) test with the automatic speed-adjusted walking pad (WP) test as a functional evaluation for COPD patients. <bold>METHODS:</bold> COPD patients aged over 40 were enrolled. Each patient completed two sets of tests, conducted 2-4 weeks apart. The first set alternated between the standard 6MWT on a HW and a WP, while the second set reversed the order. After finishing each 6MWT, a 3-hour resting and relaxing period was required before starting another test. Baseline characteristics, 6MWD, pre-/post-test vital signs, and modified Borg dyspnea scales were collected. <bold>RESULTS:</bold> Twenty COPD patients participated, primarily males (95%) with an average age of 68.5 ± 4.4 years, BMI 23.1 +/- 3.4 kg/m2, and the GOLD classification of A (50%) and B (25%). The HW 6MWD was significantly longer than the WP 6MWD (466.4 ± 68.1 meters vs. 294.0 ± 85.1 meters, p < 0.001). Both tests demonstrated good repeatability (r = 0.836 for standard 6MWT, r = 0.620 for walking pad, p < 0.001). <bold>CONCLUSION:</bold> The walking pad cannot replace the standard 6MWT on a 30-meter hallway. Despite this, both tests exhibited good internal validation and repeatability.

Authors

Institutions

Publication Details

Published
2024-09-14
DOI
https://doi.org/10.1183/13993003.congress-2024.pa5037
Primary Topic
Chronic Obstructive Pulmonary Disease (COPD) Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison between standard 6 minutes field walk test and walking pad for functional evaluation in patients with chronic lung disease

Amornpun Wongkarnjana, Nuwara Pornawalai
Chronic Obstructive Pulmonary Disease (COPD) Research
article

Comparison between standard 6 minutes field walk test and walking pad for functional evaluation in patients with chronic lung disease

Amornpun Wongkarnjana, Nuwara Pornawalai
article en

Abstract

<bold>Comparison between standard 6 minutes field walk test and walking pad for functional evaluation in patients with chronic lung disease</bold> <bold>BACKGROUND:</bold> The standard 6-minute field walk test (6MWT) is commonly used for functional evaluation in chronic obstructive pulmonary disease (COPD). However, its practicality is hindered by the requirement for a 30-meter hallway. Performing the test on a walking pad may enhance convenience, particularly in centers with limited space. <bold>OBJECTIVES:</bold> To compare the 6-minute walk distance (6MWD) by the standard hallway (HW) test with the automatic speed-adjusted walking pad (WP) test as a functional evaluation for COPD patients. <bold>METHODS:</bold> COPD patients aged over 40 were enrolled. Each patient completed two sets of tests, conducted 2-4 weeks apart. The first set alternated between the standard 6MWT on a HW and a WP, while the second set reversed the order. After finishing each 6MWT, a 3-hour resting and relaxing period was required before starting another test. Baseline characteristics, 6MWD, pre-/post-test vital signs, and modified Borg dyspnea scales were collected. <bold>RESULTS:</bold> Twenty COPD patients participated, primarily males (95%) with an average age of 68.5 ± 4.4 years, BMI 23.1 +/- 3.4 kg/m2, and the GOLD classification of A (50%) and B (25%). The HW 6MWD was significantly longer than the WP 6MWD (466.4 ± 68.1 meters vs. 294.0 ± 85.1 meters, p < 0.001). Both tests demonstrated good repeatability (r = 0.836 for standard 6MWT, r = 0.620 for walking pad, p < 0.001). <bold>CONCLUSION:</bold> The walking pad cannot replace the standard 6MWT on a 30-meter hallway. Despite this, both tests exhibited good internal validation and repeatability.

King Chulalongkorn Memorial Hospital (TH)
Good health and well-being
Openalex Percentile: Top 64%
Chronic Obstructive Pulmonary Disease (COPD) Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.